Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yang, Cuna | Yang, Leib; * | Gao, Guo-Dongb | Zong, Hui-Qiana | Gao, Duob
Affiliations: [a] Department of Medical Equipment, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, China | [b] Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, China
Correspondence: [*] Corresponding author: Lei Yang, Department of Medical imaging, The Second Hospital of Hebei Medical University, No. 215 Hepingxi Road, Xinhua District, Shijiazhuang, Hebei 050000, China. E-mail: yangcun1679@163.com.
Abstract: BACKGROUND: Artificial intelligence (AI) technology is a promising diagnostic adjunct in fracture detection. However, few studies describe the improvement of clinicians’ diagnostic accuracy for nasal bone fractures with the aid of AI technology. OBJECTIVE: This study aims to determine the value of the AI model in improving the diagnostic accuracy for nasal bone fractures compared with manual reading. METHODS: A total of 252 consecutive patients who had undergone facial computed tomography (CT) between January 2020 and January 2021 were enrolled in this study. The presence or absence of a nasal bone fracture was determined by two experienced radiologists. An AI algorithm based on the deep-learning algorithm was engineered, trained and validated to detect fractures on CT images. Twenty readers with various experience were invited to read CT images with or without AI. The accuracy, sensitivity and specificity with the aid of the AI model were calculated by the readers. RESULTS: The deep-learning AI model had 84.78% sensitivity, 86.67% specificity, 0.857 area under the curve (AUC) and a 0.714 Youden index in identifying nasal bone fractures. For all readers, regardless of experience, AI-aided reading had higher sensitivity ([94.00 ± 3.17]% vs [83.52 ± 10.16]%, P< 0.001), specificity ([89.75 ± 6.15]% vs [77.55 ± 11.38]%, P< 0.001) and AUC (0.92 ± 0.04 vs 0.81 ± 0.10, P< 0.001) compared with reading without AI. With the aid of AI, the sensitivity, specificity and AUC were significantly improved in readers with 1–5 years or 6–10 years of experience (all P< 0.05, Table 4). For readers with 11–15 years of experience, no evidence suggested that AI could improve sensitivity and AUC (P= 0.124 and 0.152, respectively). CONCLUSION: The AI model might aid less experienced physicians and radiologists in improving their diagnostic performance for the localisation of nasal bone fractures on CT images.
Keywords: Nasal bone fracture, artificial intelligence, sensitivity, specificity, deep learning
DOI: 10.3233/THC-220501
Journal: Technology and Health Care, vol. 31, no. 3, pp. 1017-1025, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl