Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mo, Ting-Ting1 | Zhu, Yun-Sen1 | Zhang, Jiang-Nan | Zhang, Wei-Kang | Jiang, Chang*
Affiliations: Department of Arthroplasty, First People’s Hospital of Wenling, Wenling, Zhejiang, China
Correspondence: [*] Corresponding author: Chang Jiang, Department of Arthroplasty, First People’s Hospital of Wenling, No. 333 Chuan’an South Road, Wenling, Zhejiang 317500, China. E-mail: changjiang2356@outlook.com.
Note: [1] These authors contributed equally to this article.
Abstract: BACKGROUND: Total hip replacement (THR) for Crowe type IV developmental dysplasia of the hip (DDH) is still challenging due to specific joint deformities and the high incidence of post-operative complications. OBJECTIVE: This study aimed to evaluate the clinical effect of trochanteric slide osteotomy (TSO) combined with a cementless femoral conical stem in THR for the treatment of Crowe type IV DDH. METHODS: Thirty-one total hip replacements (26 patients) with Crowe type IV DDH were performed using TSO combined with a cementless femoral conical stem. Surgical outcomes were evaluated using leg length discrepancy (LLD), Harris hip score, and post-operative complications. RESULTS: The average pre-operative LLD was 51 mm (range 46–58 mm), decreasing to an average of 10 mm (range 8–12 mm) post-operatively. As a result, the post-operative incidence of the Trendelenburg sign significantly decreased compared with the pre-operative incidence (P< 0.05). Bony union was identified in 26 hips (83.9%), fibrous union in four (12.9%), and non-union in one (3.2%). No acetabular or femoral component loosening, dislocation, or deep infection around the component was found in any of the patients during the follow-up period (27 to 39 months). The average Harris hip score improved from 63.0 ± 3.0 (range 58–69) to 93.3 ± 2.0 (range 91–96). CONCLUSION: TSO combined with a cementless conical stem in THR is an appropriate option for patients with high congenital hip dislocation.
Keywords: Hip dysplasia, hip replacement, greater trochanter, slide osteotomy, conical stem
DOI: 10.3233/THC-220147
Journal: Technology and Health Care, vol. 31, no. 2, pp. 553-563, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl