Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sharma, Swatia | Makkar, Monikab | Luthra, Reenab | Arora, Surajc | Pathania, Poonamd | Das, Gotame; * | Chaturvedi, Saurabhe
Affiliations: [a] Department of Dentistry, Tata main Hospital, Jamshedpur, India | [b] Department of Prosthodontics, Swami Devi Dyal Hospital and Dental College, Panchkula, Haryana, India | [c] Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia | [d] Department of Prosthodontics, Luxmi Bai Dental College, Patiala, Punjab, India | [e] Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
Correspondence: [*] Corresponding author: Gotam Das, Department of Prosthodontics, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia. E-mails: drgotam2000@gmail.com and gmenghwar@kku.edu.sa.
Abstract: BACKGROUND: Endodontically treated teeth are structurally more susceptible to root fractures. Proper tooth restorations with digitally fabricated or fibre post following endodontic therapy is essential to restore function and esthetics. OBJECTIVE: The aim of this in vitro study is to evaluate the fracture load of digitally fabricated and prefabricated fibre posts in endodontically treated teeth. METHODS: Sixty extracted human single rooted teeth were selected. The crowns were sectioned at the cement-enamel junction to standardize the remaining root length at 15 mm from the apices. Cleaning, shaping and obturation was done using conventional step back technique to an ISO K-file size 40. The roots were divided into two groups of 30 samples each: Group S: teeth reinforced with digitally fabricated posts; Group F: teeth reinforced with fibre posts. Each group was further divided into three subgroups (S7, S9, S12, F7, F9, F12) based on lengths 7, 9 and 12 mm at which the posts were cemented. Composite resin core was fabricated and prepared to receive a complete metal crown. Universal testing machine was used to measure the compressive load required to fracture the teeth. RESULTS: The highest fracture resistance of 1532N was observed with fibre posts at 12 mm of post space length followed by digitally fabricated post 1398N at 12 mm, but the difference was not statistically significant. CONCLUSION: The highest fracture resistance was observed in the teeth restored with fibre posts with 12 mm length and the lowest with digitally fabricated post with 7 mm length. As the length of post increases irrespective of type of post fracture resistance increased.
Keywords: Post and core, glass fibre post, digitally fabricated post, endodontically treated teeth, fracture resistance
DOI: 10.3233/THC-213690
Journal: Technology and Health Care, vol. 31, no. 2, pp. 447-458, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl