Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zor, Zeynep Fatmaa; * | Kılınç, Yeliza | Erkmen, Erkana | Kurt, Ahmetb
Affiliations: [a] Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University, Ankara, Turkey | [b] Department of Manufacturing Engineering, Faculty of Engineering, Atılım University, Ankara, Turkey
Correspondence: [*] Corresponding author: Zeynep Fatma Zor, Faculty of Dentistry, Gazi University, Bişkek Cd. (8. Cd) 1.Sk. No:4 06490 Emek, Ankara, Turkey. E-mail: ftmzor@gmail.com.
Abstract: BACKGROUND: The effect of different thread designs and diameters on the all-on-four concept is unclear. OBJECTIVE: The aim of the study was to clarify the differences in stress distribution of dental implants with various thread designs and diameters based on the all-on-four concept with three dimensional (3D) finite element analysis (FEA). METHODS: A 3D model of a totally edentulous mandible was used to perform the FEA. Four different models (M1, M2, M3, and M4) including 3.5 and 4.3 mm diameter dental implants with active and passive threaded designs were generated. The dental implants were positioned according to the all-on-four concept. The Von Mises stresses on dental implants and maximum and minimum principal stresses (Pmax and Pmin) on bony structures were calculated under vertical, oblique and horizontal loads. RESULTS: For Von Mises stresses, the highest stress values were detected on the distal implants for all models. Distal implants had also the highest stress values for vertical loading. The Von Mises stresses were found to be concentrated around the implant’s neck. In all models the highest Pmax and Pmin stresses occurred in the bone surrounding the distal implant. It was noted that the active threaded implants showed the highest Pmax and Pmin stress values. CONCLUSION: The implant thread design and diameter might have a strong influence on the stress values in the all-on-four concept.
Keywords: All-on-four, dental implant, diameter, finite element analysis, thread design
DOI: 10.3233/THC-213072
Journal: Technology and Health Care, vol. 30, no. 5, pp. 1031-1042, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl