Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Jiea | Ye, Pinga | Zhang, Lizhengb | Wu, Hongliub | Chi, Tianxib | Chang, Zhaohuaa; b; *
Affiliations: [a] Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China | [b] Department of R&D of Special Equipment and Product, Institute of Microport Engineering, Shanghai MicroPort Medical (Group) Co., Ltd. Shanghai, China
Correspondence: [*] Corresponding author: Zhaohua Chang, Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China. E-mail: m8090313@126.com.
Abstract: BACKGROUND:The treatment of adolescent patients with distal femoral cancer has always been a concern. The limb-salvage, regarded as a mainstream treatment, had been developed in recent years, but its application in children still remains challenging. This is because it can lead to potential limb-length discrepancy from the continued normal growth of the contralateral lower body. The extendable prosthesis could solve this problem. The principle is that it can artificially control the length of the prosthesis, making it consistent with the length of the side of the lower limbs. However, this prosthesis has some complications. The extendable prosthesis is classified into invasive and minimally invasive, which extends the prosthesis with each operation. OBJECTIVE:We designed a new non-invasive prosthesis that can be extended in the body. Based on the non-invasive and extendable characteristics, we need to verify the supporting performance of this prosthesis. METHODS: We carried out a mechanical testing method and finite element analysis simulation. CONCLUSION:The support performance and non-invasively extension of this prosthesis were verified.
Keywords: Osteosarcoma, limb salvage, non-invasive extendable prosthesis, loading test, finite element analysis
DOI: 10.3233/THC-202420
Journal: Technology and Health Care, vol. 29, no. 5, pp. 1001-1009, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl