Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chaturvedi, Saurabh* | Alqahtani, Nasser M. | Addas, Mohamed Khaled | Alfarsi, Mohammed A.
Affiliations: Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
Correspondence: [*] Corresponding author: Saurabh Chaturvedi, Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia. Tel.: +966 580697248; E-mail: survedi@kku.edu.sa.
Abstract: BACKGROUND: Clinicians routinely provide provisional crowns following teeth preparation. Three-dimensional (3D) printing technology could be used over conventional methods for better fit as lack of adequate fit would result in plaque accumulation, micro-leakage, teeth sensitivity, caries and periodontal diseases. OBJECTIVE: The aim of the study was to evaluate the marginal and internal fit of provisional crowns fabricated using 3D printing technology and to compare it with that of compression molding and milling methods. METHODS: Ninety study models were fabricated by duplicating metal master models of the maxillary first premolar molar with three different finish line chamfer, rounded shoulder and rounded shoulder with bevel. On each study model, provisional crowns were fabricated using compression molding (Mo. group, n= 30 – by over impression technique), milling (Mi. group, n= 30 – by 5-axis dental milling machine), and 3D printing method (3D-P. group, n= 30 – by 3D printer). Marginal and internal fit of the samples were evaluated by measuring gap using a scanning electron microscope with a magnification of 27 ×, at 7 zones A–G on different finish line models. The data were statistically analysed using one-way analysis of variance (ANOVA) at the 0.05 significance level. The p-values were calculated using Dunnett’s test. RESULTS: The marginal gap was minimal for the 3D-P. group for each finish line with lowest for rounded shoulder with bevel at zone A 30.6 ± 5.3 and at zone G 32.8 ± 5.4. In axial area, i.e. zones B and F, the minimum gap was noticed for the Mo. group and in Occlusal area (cusp and fossa), for zones C–E maximum gap was determined in Mi. group followed by Mo. and 3D-P. groups. CONCLUSIONS: 3D printed provisional crowns have better marginal and internal fit compared to milled and molded provisional crowns.
Keywords: Temporary crown, additive manufacturing, internal discrepancy, 3D printing, CAD-CAM
DOI: 10.3233/THC-191964
Journal: Technology and Health Care, vol. 28, no. 6, pp. 635-642, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl