Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dakhil, Nawfala | Evin, Morganea | Llari, Maximea | Mo, Fuhaoc | Thefenne, Laurentb | Liu, Tangd | Behr, Michela; *
Affiliations: [a] Aix-Marseille University, IFSTTAR, Laboratoire de Biomécanique Appliquée, Marseille, France | [b] Service de Médecine Physique et Réadaptation, Hôpital Laveran, Marseille, France | [c] College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan, China | [d] The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
Correspondence: [*] Corresponding author: Michel Behr, Aix-Marseille University, IFSTTAR, LBA, Marseille, France. Tel.: +33 4 91 65 80 14; E-mail: michel.behr@ifsttar.fr.
Abstract: BACKGROUND: Prosthetic rehabilitation improves the overall quality of life of patients, despite discomfort and medical complications. No quantitative assessment of prosthesis-patient interaction is used in routine protocols and prosthesis quality still results from the manufacturer’s know-how. OBJECTIVE: Our objective is to investigate whether pressure can be a relevant factor for assessing socket adequacy. METHODS: A total of 8 transtibial amputee volunteers took part in this experimental study. The protocol included static standing and 2 minutes walking tests while the stump-to-socket interface pressures were measured. Questionnaires on comfort and pain were also conducted. RESULTS: During static standing test, maximum pressures were recorded in the proximal region of the leg, with a peak value reaching 121.1 ± 31.6 kPa. During dynamic tests, maximum pressures of 254.1 ± 61.2 kPa were recorded during the loading phase of the step. A significant correlation was found between the pain score and static maximum recorded pressure (r= 0.81). CONCLUSIONS: The protocol proposed and evaluated in this study is a repeatable, easy-to-set quantified analysis of the patient to socket interaction while standing and walking. This approach is likely to improve feedback for prosthesis manufacturers and consequently the overall design of prostheses.
Keywords: Prosthetic socket, rehabilitation, pain measurement, patient satisfaction, transtibial amputee, gait ability, comfort assessment, transtibial prosthetic socket
DOI: 10.3233/THC-191637
Journal: Technology and Health Care, vol. 27, no. 6, pp. 669-677, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl