Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Advances in Biomedical Engineering: Research that bridges the gap between Engineering and Medicine
Guest editors: Julius Griškevičius.
Article type: Other
Authors: Bubulis, Algimantasa | Venslauskas, Mantasa | Navickas, Jonasa | Abramavičius, Silvijusb; * | Stankevičius, Edgarasb
Affiliations: [a] Institute of Mechatronics, Kaunas University of Technology, Kaunas, Lithuania | [b] Institute of Physiology and Pharmacology, Lithuanian University of Health Sciences, Kaunas, Lithuania
Correspondence: [*] Corresponding author: Silvijus Abramavicius, Institute of Physiology and Pharmacology, Lithuanian University of Health Sciences, A. Mickeviciaus str. 9, Kaunas LT-44307, Lithuania. Tel.: +370 68644690; E-mail: silvijus2@yahoo.com.
Abstract: BACKGROUND: Majority of limb amputations are caused by circulatory disturbances such as vascular occlusions and strictures. Discovery of modern and more advanced ultrasonic interventional vascular debulking methodology would likely save limbs of CVD patients and their lives in an economical way. However, there is a lack of researches regarding the ultrasound’s effect on physiological functions of human blood cells. The tube-shaped ultrasound waveguide wire with orifices at its operational end was offered as the alternative to some currently patented interventional thrombosis treatment solutions. OBJECTIVE: To establish the safe operating regime of the proposed device. METHODS: The temperature rise induced by the cavitation process and friction between the waveguide and surrounding fluids was measured and microscopic pictures of human blood were made. RESULTS: Blood insonation lasting 15 seconds, leads to blood clot formation. If insonation continues for 30 seconds some cells are totally destroyed. In addition, the safe operating regime was established. To avoid heating of the environment to the temperature harmful for the medium (blood) and surrounding tissues, is achieved when the system should be on for 40%, and of for 60% of the period of 1 second. CONCLUSIONS: The safe operating regime of the proposed device was established.
Keywords: Cavitation, ultrasound, peripheral artery disease, cardiovascular diseases
DOI: 10.3233/THC-182509
Journal: Technology and Health Care, vol. 26, no. S2, pp. 625-634, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl