Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kan, Chung-Danna; * | Wang, Jieh-Nengb | Lin, Chia-Hungc; * | Chen, Wei-Lingd | Lu, Pong-Jeue | Chan, Ming-Yaoe | Wu, Jui-Tef
Affiliations: [a] Division of Cardiovascular Surgery, College of Medicine, National Cheng Kung University, Tainan, Taiwan | [b] Department of Pediatrics, National Cheng Kung University Hospital Tainan, Tainan, Taiwan | [c] Department of Electrical Engineering, Kao-Yuan University, Kaohsiung, Taiwan | [d] Department of Engineering and Maintenance, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan | [e] Heart Science and Medical Devices Research Center, National Cheng Kung University, Tainan, Taiwan | [f] Department of Veterinary Medicine, National Chiayi University, Chiayi, Taiwan
Correspondence: [*] Corresponding authors: Chung-Dann Kan, Division of Cardiovascular Surgery, College of Medicine, National Cheng Kung University, Tainan, Taiwan. E-mail: kcd56@mail.ncku.edu.tw.Chia-HungLin,DepartmentofElectricalEngineering,NationalChin-YiUniversityofTechnology,TaichungCity,Taiwan,E-mail:eechl53@gmail.com.
Abstract: Pulmonary valve diseases include the different degrees of aortic stenosis or congenital defects in children or adults. Valve repair or replacement surgery is commonly performed to relieve valvular dysfunction and improve the significant flow regurgitation in the aortic valve and the pulmonary valve. However, commercial valve stents and valved conduits are sometimes not available for children or patients with special conditions. The handmade trileaflet valve design has been used with different range of diameters for patch-valved conduit reconstruction. Thus, we propose a multiple regression model, as a generalized regression neural network (GRNN), to determine the optimal trileaflet parameters, including the width, length, and upper lower curved structure. Through computed tomography pulmonary angiography, while the diameter of the main pulmonary artery is determined, a leaflet template can be rapidly sketched and made. Using an experimental pulmonary circulation loop system, the efficacy of the valved conduit can be validated using the regurgitation fraction method. In contrast to commercial valve stents, experimental results indicate that the handmade trileaflet valve can also improve severe pulmonary regurgitations.
Keywords: Handmade trileaflet valve, valve replacement, generalized regression neural network (GRNN), regurgitation fraction (RF)
DOI: 10.3233/THC-171064
Journal: Technology and Health Care, vol. 26, no. 4, pp. 605-620, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl