Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zeinali-Rafsanjani, Banafsheha; b | Mosleh-Shirazi, Mohammad Aminb; c | Haghighatafshar, Mahdia | Jalli, Rezab | Saeedi-Moghadam, Mahdib; *
Affiliations: [a] Nuclear Medicine and Molecular Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran | [b] Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran | [c] Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
Correspondence: [*] Corresponding author: Mahdi Saeedi-Moghadam, Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran. Tel.: +98 71 36125320; E-mail: m_saeedimoghadam@yahoo.com.
Abstract: BACKGROUND:Microbeam radiotherapy (MRT) is a treatment in which radiation field is divided into several separate fields of 10–100 μm width and 100–400 μm spacing. In this treatment, normal tissue can tolerate high doses that are delivered to its small volumes. OBJECTIVE:MCNPX 2.4 Monte Carlo code was used to calculate the dose distribution of MRT in a lung tumor in a simulated Rando phantom. METHODS:The effects of tissue inhomogeneities, using contrast media and changing the number of beams were investigated. Dose volume histograms and beam profiles of target and organs at risk were assessed and the dose uniformity in the target region was evaluated using homogeneity. The conformity indices also used to quantify the conformation of the shape of prescribed isodose volume to the shape and size of the target. RESULTS:Tissue inhomogeneity of this region did not interfere significantly with target dose homogeneity. The use of contrast media or increasing the number of beams improved target dose homogeneity and decreased the dose to surrounding tissues. CONCLUSIONS: The results suggest that further investigation and evaluation of MRT for treatment of chest tumors is worthwhile.
Keywords: Microbeam radiotherapy, dose volume histogram, homogeneity index, conformity index
DOI: 10.3233/THC-170818
Journal: Technology and Health Care, vol. 25, no. 4, pp. 683-692, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl