Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bredow, J.a; 1; * | Beyer, F.b; 1 | Oppermann, J.a | Kraus, B.c | Meyer, C.a | Stein, G.a | Eysel, P.a | Koy, T.d
Affiliations: [a] Department of Orthopedic and Trauma Surgery, University Hospital of Cologne, Cologne, Germany | [b] Department of Orthopedic and Trauma Surgery, Marien Krankenhaus gGmbH, Bergisch Gladbach, Germany | [c] Department of Radiology, University Hospital of Düsseldorf, Düsseldorf, Germany | [d] Department of Spine Surgery, KLINIK am RING, Cologne, Germany
Correspondence: [*] Corresponding author: Jan Bredow, Department of Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Strasse 62, D-50937 Cologne, Germany. Tel.: +49 221 478-87294; Fax: +49 221 478-87296; E-mail:jan.bredow@uk-koeln.de
Note: [1] Equal contributors.
Abstract: BACKGROUND: Goal of this study is to present an easily reproducible and reliable measurement to evaluate accuracy of screw placement in cervical spine. METHODS: Accuracy of cervical screw position was assessed in 52 patients treated with 163 screws. Each patient receiving pedicle, transarticular C1/2, lateral mass, or laminar screws and postoperative CT scan was included. Placement position was categorized in 5 grades: Grade 1 is ideal with pedicle wall perforation < 1 mm, grade 2 < 2 mm, grade 3 < 3 mm, and grade 4 < 4 mm. Grade 5 > 4 mm and/or obstruction of transverse foramen by more than half a screw diameter. Intraclass correlation coefficient (ICC) values were assessed for inter- and intraobserver reliability. RESULTS: The mode of individual evaluations was calculated to assign a single value to each screw. This yielded 89 grade 1 (54.6%), 48 grade 2 (29.4%), 14 grade 3 (8.6%), 3 grade 4 (1.8%), and 9 grade 5 (5.5%) screws. Intraobserver reliability ICC was 0.966 and 0.959 for measurements. Interobserver reliability ICC was 0.938. CONCLUSION: This study introduces a reliable classification of cervical spine instrumentation with various screw types. This should enable the use of a uniform and reproducible, and thus comparable classification for screw position in cervical spine.
Keywords: Classification, screw placement accuracy, cervical spine, spondylodesis
DOI: 10.3233/THC-161246
Journal: Technology and Health Care, vol. 24, no. 6, pp. 919-925, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl