Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lin, Chia-Hunga; * | Kan, Chung-Dannb; * | Chen, Wei-Lingc | Wu, Ming-Juid | Yu, Fan-Minge
Affiliations: [a] Department of Electrical Engineering, Kao-Yuan University, Kaohsiung, Taiwan | [b] Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan | [c] Department of Engineering and Maintenance, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan | [d] Department of Internal Medicine, Kaohsiung Veterans General Hospital, Tainan Branch, Tainan, Taiwan | [e] Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan, Taiwan
Correspondence: [*] Corresponding author: Chia-Hung Lin, Department of Electrical Engineering, Kao-Yuan University, Kaohsiung 82151, Taiwan. E-mail: eechl53@gmail.com; Chung-Dann Kan, Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70101, Taiwan. E-mail: kcd56@mail.ncku.edu.tw
Abstract: Narrowed vessel accesses produce blood flow changes, and induce flow instability and vessel wall vibration, resulting in blood pressure, flow velocity, and flow resistance increases. The vessel wall vibrates and propagates the low axial blood flow, as representing the resistance (R) to blood flow. The compliance is a blood pressure-blood volume relation, representing the systole and diastole capacity of the blood vessel. These dynamic behaviors increase blood flow resistances and reduce blood vessel compliances. Vibration phenomena result on the elastic vessel walls and induce simple harmonic motion due to transverse vibration pressure (TVP). The rise time, amplitude, and pulse duration of transverse waves are determined by the flow resistances (R) and vessel compliances (C). Thus, a stenotic arteriovenous access has high resistance and low compliance, which can be expressed an astable multivibrator as an equivalent model consisting of a lumped resistor (R) and a lumped capacitor (C). TVP's oscillation frequency, rise time, and amplitude are determined by the flow resistances and vessel compliances. Hence, an astable multivibrator is used to model TVP parameters to estimate negative time constants, τ=(R× C), which are used to evaluate the flow instability and the dysfunction risk in in-vitro arteriovenous grafts (AVGs). Experimental results show the average negative time constants have the positive correlation as the degree of stenosis (DOS) increases (R2 = 0.8944), and their variations with the flow resistance and vessel compliance are also validated. Positive pole values, s=(-1/τ), are used to show that the force responses of the vessel walls grow in a finite time, 0.5415 ± 7.60 × 10-3 sec, and the equivalent model would be also unstable as DOS increases (R2 = 0.8802). By comparison with hemodynamic analysis, the finding of proposed model can be further carried out for screening AVG dysfunction risk during hemodialysis treatment.
Keywords: Astable multivibrator, transverse vibration pressure (TVP), degree of stenosis (DOS), time constant, positive pole
DOI: 10.3233/THC-161130
Journal: Technology and Health Care, vol. 24, no. 3, pp. 295-308, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl