Abstract: Considering biomechanics of oral implants, both loading on the implant itself and the transferred load to the bone need our attention. Mastication induces vertical and transverse forces, which induce axial forces and bending moments and exert stress gradients in the implant as well as in the bone. By the use of strain gauges or piezo-electric force transducers, one succeeds in precise intra-oral force measurements which make it possible to study a wide range of varying conditions in implant dentistry. A key determinant of the success or failure of an oral implant is the way mechanical stresses are transferred to the surrounding bone. The load transfer from implants to surrounding bone depends on the type of loading, the bone-implant interface, the length and diameter of the implants, the implant shape, structure of the implant surface, the superstructure and the quality and quantity of the surrounding bone. Finite element analyses indicate maximum stress concentrations in the contact area of the implants with the cortical bone and around the apex of the implants in the trabecular bone. Although the precise mechanisms are not fully understood, it is clear that there is an adaptive remodelling response of the surrounding bone to the current situation.
Keywords: Biomechanics, oral implants, oral prosthesis, loading
DOI: 10.3233/THC-1997-5401
Journal: Technology and Health Care, vol. 5, no. 4, pp. 253-273, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl