Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Langton, C.M. | Ballard, P.A. | Langton, D.K. | Purdie, D.W.
Affiliations: Centre for Metabolic Bone Disease, Hull, UK
Abstract: Bone mineral density (BMD) referral for dual energy X-ray absorptiometry (DXA) is generally based upon agreed clinical referral criteria (CRC). The aim of this study was to determine whether ultrasound measurements of Broadband Ultrasound Attenuation (BUA) and velocity (VOS) provide a superior selective pre-screen referral method for BMD assessment by DXA. 107 women aged 60–69 years (64.2 ± 2.8) had BMD measurements at lumbar spine and right femoral neck along with ultrasound BUA and VOS measurements of the left calcaneus. Each subject completed an extensive clinical and social questionnaire to ascertain those who would have met one or more of the five general clinical referral criteria adopted by our Centre. Each subject was classified by DXA using the WHO criteria as normal, osteopenic or osteoporotic at lumbar spine or femoral neck. The cost per osteoporotic subject correctly identified was calculated. As a reference, based upon DXA measurements alone on all 107 subjects, the cost per osteoporotic subject identified would be £ 185. If subjects had been referred using the clinical referral criteria the cost is £ 171. For assessment of referral by BUA or VOS, an additional charge for ultrasound measurement of all subjects was incorporated. At a BUA of 60 dB MHz−1 the cost per osteoporotic subject is £ 107. Ultrasound velocity or a combination of BUA or VOS with clinical referral criteria did not provide a significantly reduced cost than the current clinical referral criteria alone. This study has demonstrated that BUA provides an improved referral procedure to that currently achieved with clinical referral criteria and supports the concept of BUA being used as a selective pre-screen for DXA in 7th decade subjects.
DOI: 10.3233/THC-1997-5306
Journal: Technology and Health Care, vol. 5, no. 3, pp. 235-241, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl