Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Redmann, K.a | Lunkenheimer, P.P.a | Scheld, H.H.a | Dietl, K.-H.b | Fischer, St.c | Cryer, C.d | Whimster, W.F.e | Stroh, N.f
Affiliations: [a] Klinik und Poliklinik für Thorax-, Herz- und Gefäßchirurgie, Münster, Germany | [b] Klinik und Poliklinik für Chirurgie, Münster, Germany | [c] Klinik und Poliklinik für Anästhesie und operative Intensivmedizin, Universität Münster, Münster, Germany | [d] Institut für Numerische Mathematik, Universität Münster, Münster, Germany | [e] Department of Histopathology, King’s College School of Medicine and Dentistry, London, UK | [f] Fraunhoferinstitut für Grenzflächen- und Bioverfahrenstechnik, Stuttgart, Germany
Abstract: Microergometry is a method which we have developed as a tool to measure local mesh-tension within the myocardial weave at any measuring site of both ventricles and the septum on the beating heart in situ. In a mapping procedure on pig and dog hearts, both in control conditions and in the hypertrophied state after aortic banding, local mesh-tension was measured in several areas and in up to eight depths proceeding from the epicardium to the endocardium: Probe-to-fibre coupling is definitely more stable in the canine myocardium than in the porcine heart muscle, probably due to a more effective connective tissue fettering of the canine myocardial weave. The observed longitudinal gradient, with the highest tension in the base, of control dog hearts was levelled out in the hypertrophied hearts. Furthermore, in control dog hearts mesh-tension in the subepi- and subendocardial layers was higher than in the midlayers. This pronounced midlayer-hypotension was smoothed in the hypertrophied hearts. Further studies will be dedicated to the question of whether the impact of ventricular size and shape on intersegmental stress transmission is determined by the Frank–Starling mechanism alone or whether protracted remodelling processes on the level of the local fibre weave cause slow coupling alterations.
DOI: 10.3233/THC-1997-51-211
Journal: Technology and Health Care, vol. 5, no. 1-2, pp. 123-134, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl