Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Alam, K.
Affiliations: Department of Mechanical and Industrial Engineering, College of Engineering, Sultan Qaboos University, P.O. Box 33, Al-Khoud 123, Sultanate of Oman. Tel.: +968 24143751; Fax: +968 24141316; E-mail: kalam@squ.edu.om
Abstract: Background:Bone cutting is a well-known surgical procedure in orthopaedics and dentistry for fracture treatment and reconstruction. Common complications associated with the process are mechanical damage linked with excessive levels of penetration force. Larger forces may produce minor cracks in bone which may seriously affect strength of fixation and may delay the healing process. Objective:This paper investigates cracking behavior in the microstructure of cortical bone in cutting using experimental and numerical techniques. Methods:Experiments were performed on cortical bone to study the mechanics of crack propagation and evaluate the extent of crack with the drilling force and amount of penetration. Finite element (FE) simulations were performed to visualize the extension and arrest of the cracks in bone microstructure. Results:The length of crack was found to be strongly influenced by the drilling force and amount of drill penetration. Osteon were seen to deflect the cracks at their boundaries. Crack propagation in bone microstructure was observed to depend on anatomical direction. Numerical simulations predicted the direction of crack propagation and found osteon boundaries to act as barrier to the cracks. Conclusions:Lower drilling force may be used in cutting the bone to avoid cracks in the bone tissue. A detailed FE model based on fracture data of cortical bone is to be produced to simulate cracking of bone microstructure.
Keywords: Orthopedics, bone drilling, finite element simulation, crack, drilling force, micro-CT, scanning electron microscopy
DOI: 10.3233/THC-140848
Journal: Technology and Health Care, vol. 22, no. 5, pp. 741-750, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl