Issue title: Recent Trends in Convergence-based Smart Healthcare Service
Guest editors: Sang-Yeob Ohv, Supratip Ghosew, Kyungyong Chungx, Joong-Kyung Ryuy and Jung-Soo Hanz
Article type: Research Article
Authors: Park, Sang-Suba; b; *
Affiliations: [a] Department of Emergency Medical Technology, ChungCheong University, Cheongju, Korea | [b] Graduate School of Pharmacy, Korea University, Sejong-si, Korea | [v] Department of Interactive Media, Gachon University, Seongnam, Korea | [w] Department of Computer Science and Engineering, University of Information Technology and Sciences, Dhaka, Bangladesh | [x] Department of Computer Information Engineering, Sangji University, Wonju, Korea | [y] Department of Computer Software, Daelim University, Gyeonggi-do, Korea | [z] Division of Information and Communication, Baekseok University, Seoul, Korea
Correspondence: [*] Address for correspondence: Sang-Sub Park, Graduate School of Pharmacy, Korea University, 2511, Sejong-ro, Jochiwon-eup, Sejong-si, 339-700, Korea. E-mail: wooonseo@hanmail.net.
Abstract: The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p < 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p < 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p < 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
Keywords: Cardiopulmonary resuscitation, smartphone, application, chest compression
DOI: 10.3233/THC-140791
Journal: Technology and Health Care, vol. 22, no. 3, pp. 351-358, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl