Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Saxena, Amulya K.
Affiliations: Department of Pediatric- and Adolescent Surgery, Medical University of Graz, Auenbruggerplatz 34, A-8036 Graz, Austria. Tel.: +43 316 385 13762; Fax: +43 316 385 13775; E-mail: amulya.saxena@medunigraz.at.
Abstract: Background:Laparoscopic pyloromyotomy (LP) for Infantile Hypertrophic Pyloric Stenosis (IHPS) is associated with an increased risk of mucosal tears or incomplete myotomy when compared with open myotomy. Keeping these risks in mind, a new ergonomically designed spreader for LP was developed and investigated in IHPS. Methods:The new Pyloric Spreader was designed as a 3.5 mm instrument specifically for minimal access application taking into consideration the specific needs of LP. Results:LP was performed using this spreader in 25 infants with IHPS during a 5-year period from 2006–2012. After incising the pylorus using an arthrotomy knife blade, the spreader could be inserted with ease in the pyloric muscle slit and permitted spreading of the pyloric muscle without any circular tears. The axial handle attached to the spreader enable a wide and controlled muscular spreading without mucosal injuries or incomplete spreads. Two infants underwent surgical revision due to recurrent vomiting; however no signs of incomplete myotomy were evident and the vomiting which subsequently subsided was attributed to the preoperative administration of Rotavirus vaccines in these infants. Conclusion:The newly designed Pyloric Spreader offers a new ergonomically designed instrument with a flat tip for easy placement in the pyloric muscle slit, broad instrument surface to avoid circular muscle tears, rounded tip edges to prevent mucosal injuries, wide spreading capability for optimal muscle spread and an axial handle for better hand ergonomic for LP in IHPS.
Keywords: Laparoscopic pyloromyotomy, infantile hypertrophic pyloric stenosis, spreader, ergonomic, instrument
DOI: 10.3233/THC-130752
Journal: Technology and Health Care, vol. 21, no. 6, pp. 625-630, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl