Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mori, Futoshia; b | Nakayama, Toshioc | Matsuzawa, Teruod | Ohta, Makotoe; *
Affiliations: [a] Center for Integrated Disaster Information Research, Interfaculty Initiative in Information Studies, The University of Tokyo, Tokyo, Japan | [b] Earthquake Research Institute, The University of Tokyo, Tokyo, Japan | [c] Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan | [d] Research Center for Simulation Science, Japan Advanced Institute of Science and Technology, Ishikawa, Japan | [e] Institute of Fluid Science, Tohoku University, Sendai, Japan
Correspondence: [*] Corresponding author: Makoto Ohta, Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan. Tel./Fax: +81 22 2175309; E-mail: ohta@biofluid.ifs.tohoku.ac.jp.
Abstract: Percutaneous transluminal coronary angioplasty (PTCA) with stent implantation is widely used for the treatment of coronary stenosis. However, restenosis after stent implantation frequently reported by intravascular ultrasound evaluation. This may occur because of the reduced luminal area after implantation, insufficient stent expansion, or by the elastic recoil of the stent (ERS). Quantitative evaluation of stent expanding should provide further information on how to decrease the incidence of re-stenosis. Many previous studies have observed stent properties in 2D. However, the stent geometry is changed in 3D space, and 3D measurements will provide further information on factors such as the risk for asymmetric ERS. We performed 3D reconstruction using high spatial resolution images obtained with a Micro-CT system to observe the 3D expansion behavior of a test stent and quantitatively evaluate ERS. The expansion behavior of each structural component of the stent varied, as did the ERS and eccentricity. ERS ranged from 2.4% to 9.2% during observation form proximal and distal positions in each component. The greatest difference in ERS between 2D and 3D measurements was 5.2%. 3D measurements provide more information on ERS than 2D measurements. Our result shows the importance of the observation, and the evaluation by three dimensions.
Keywords: Three dimensional, Micro-CT, expansion behavior, elastic recoil of stent, balloon-expandable stent
DOI: 10.3233/THC-2012-0680
Journal: Technology and Health Care, vol. 20, no. 4, pp. 305-315, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl