Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Budde, Stefana; * | Windhagen, Henninga | Lerch, Matthiasa | Broese, Maximilianb | Götze, Patriccc | Thorey, Fritza
Affiliations: [a] Department of Orthopedic Surgery, Hannover Medical School, Hannover, Germany | [b] Trauma Department, Hannover Medical School, Hannover, Germany | [c] Institute of Radiology, Paul Gerhardt Stift Wittenberg, Lutherstadt Wittenberg, Germany
Correspondence: [*] Corresponding author: Dr. med. Stefan Budde, Hannover Medical School, Department of Orthopaedic Surgery, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany. Tel.: +49 0511/5354-0; E-mail: stefan.budde@ddh-gruppe.de.
Abstract: Various types of bone preserving total hip prostheses with a proximal force transmission concept have been developed for younger adults, one of these being the implant "Delfi M®", produced by ESKA until 2009. Since the demand could not meet the expectations, the production was stopped due to economic reasons so that only 31 implants of this type were sold and even less actually implanted. This study followed up 15 Delfi M® prostheses in 12 patients for 3.1 years and represents the only existing valid data about this implant. Demographical, preoperative and postoperative data including clinical scores (HOOS and mHHS) were collected retrospectively. Postoperative X-rays were analyzed by an independent radiologist. One implant had to be exchanged due to an infection and another one due to excessive implant migration. The mHHS and the HOOS scores showed a significant improvement after surgery. In the radiological analysis, there were no signs of radiolucent lines or osteolyses. This trial demonstrates good clinical and radiological midterm results for the Delfi M prosthesis. Limitations of this study are a small sample size and a follow-up time of 3 years at only one timepoint.
Keywords: Total hip arthroplasty, femoral neck preserving prosthesis, total hip replacement
DOI: 10.3233/THC-2011-0659
Journal: Technology and Health Care, vol. 20, no. 2, pp. 85-93, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl