Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Citak, M.a; * | Board, T. N.b | Sun, Y.a | Look, V.a | Krettek, C.a | Hüfner, T.a | Kendoff, D.a
Affiliations: [a] Department of Trauma Surgery, University of Hannover, Germany | [b] Wrightington Hospital and the University of Manchester, UK
Correspondence: [*] Address for correspondence: Musa Citak, MD, Trauma Department, Hannover Medical School, Carl-Neubergstr. 1, 30655 Hannover, Germany. Tel.: +49 511 532 2026; Fax: +49 511 532 5788; E-mail: citak.musa@mh-hannover.de.
Abstract: Introduction:In computer assisted orthopaedic surgery, rigid fixation of the Reference Marker (RM) system is essential for reliable computer guidance. A minimum shift of the RM can lead to substantial registration errors and inaccuracies in the navigation process. Various types of RM systems are available but there is little information regarding the relative stabilities of these systems. The aim of this study was to test the rotational stability of three commonly used RM systems. Materials and methods:One hundred and thirty Synbones and 15 cadavers were used to test the rotational stability of three different RM systems (Schanz’ screw, RM B and RM C adjustment systems). Using a specially developed testing device, the peak torque sustained by each RM system was assessed in various anatomical sites. Results:Comparison of means for Synbone showed that the RM C was the most stable (mean peak torque 5.60 ± 1.21 Nm) followed by the RM B system (2.53 ± 0.53 Nm) and the RM A (0.77 ± 0.39 Nm) (p<0.01). The order of stability in relation to anatomical site was femoral shaft, distal femur, tibial shaft, proximal tibia, anterior superior iliac spine, iliac crest and talus. Results from the cadaver experiments showed similar results. Bi-cortical fixation was superior to mono-cortical fixation in the femur (p<0.01) but not the tibia (p=0.22). Conclusion:The RM system is the vital link between bone and computer and as such the stability of the RM is paramount to the accuracy of the navigation process. In choosing RM systems for computer navigated surgery surgeons should be aware of their relative stability. Anatomical site of RM placement also affect the stability. Mono-cortical fixation is generally less stable than bi-cortical.
DOI: 10.3233/THC-2007-15603
Journal: Technology and Health Care, vol. 15, no. 6, pp. 407-414, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl