Article type: Research Article
Authors: Fankhauser II, Franz
Affiliations: Department of Ophthalmology, Städtisches Klinikum, Auenweg 38, D-06847 Dessau, Germany. Tel.: +49 340 501 4500; Fax: +49 340 501 4570; E-mail: franz.fankhauser@klinikum-dessau.de
Abstract: Objective:To detect post-op molecular changes and inflammatory processes by dynamic light scattering (DLS) in eye segments. To develop DLS parameters which are appropriate for the control of post-op course after ophthalmologic surgery. Methods, design:Three new DLS devices were tested in different post-op clinical settings such as pseudoexfoliation syndrome (PEX), cataract surgery and retinal surgery. In a second step DLS was used to detect molecular changes in the cornea of 6 patients after photo refractive keratectomy (PRK) and 16 patients after photo astigmatic refractive keratectomy (PARK). Results:In PEX-patients cataract surgery changed the DLS signals of the anterior chamber and the lens in a specific way compared to the pre-op situation. Cataract patients without PEX had more scattering particles post-op and retinal surgery modified the DLS signal of the vitreous. Furthermore it was shown that the length of the corneal scattering vector l correlated with the process of the corneal wound healing after PARK. One and three months after surgery the lengths of the scattering vectors had increased significantly but returned to pre-op values twelve months post-op. Discussion:The post-op transparency of eye segments such as the cornea, the vitreous and the anterior chamber depends primarily on the wound healing mechanisms. DLS seems to be a suitable method to control the corneal recovery after refractive surgery. Conclusions:The length of the scattering vector l correlates well with the wound healing after refractive surgery. However DLS-signals seem to contain information about the molecular composition of tissue too. Therefore further research is needed to refine the interpretation of the DLS signals.
DOI: 10.3233/THC-2007-15403
Journal: Technology and Health Care, vol. 15, no. 4, pp. 247-258, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl