Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Synergy of Informatics and Biology – Grand Challenge of Bio-nantechnology Based Future Biomedical Engineering
Guest editors: Toshiyuki Hayase and Atsushi Shirai
Article type: Research Article
Authors: Fukui, Tomohiroa; * | Parker, Kim H.b | Tsubota, Ken-ichia | Wada, Shigeoa | Yamaguchi, Takamia
Affiliations: [a] Department of Bioengineering and Robotics, Tohoku University, Graduate School of Engineering, Aoba 6-6-01, Aoba-ku, Sendai, Miyagi 980-8579, Japan | [b] Physiological Flow Studies Group, Department of Bioengineering, Imperial College, London SW7 2AZ, UK | Institute of Fluid Science, Tohoku University, Japan
Correspondence: [*] Corresponding author: Tomohiro Fukui, Tel.: +81 22 795 6958; Fax: +81 22 795 6959; E-mail: fukui@pfsl.mech.tohoku.ac.jp.
Abstract: Pulse Wave Velocity (PWV) is recognized by clinicians as an index of the mechanical properties of human blood vessels. However, the measured PWV of real human blood vessels will not always obey the Moens-Korteweg equation, which describes the PWV in ideal elastic tubes. Waveform analysis has been studied as an alternative diagnosis for cardiovascular disease, and reflected waves that occur in the diseased region may be a key for the estimation of the severity of disease. In this study, we modeled stenosed and aneurysmal arteries in a three-dimensional coupled fluid-solid interaction scheme, and analyzed the pulse wave propagation in order to assess the reflected waves that occurred in the diseased region. A commercial code (Radioss, MECALOG, France) was used to solve the fluid-solid interactions. A steady flow with Reynolds number 1000 was imposed at the inlet of the artery as the basic flow, then a single rectangular pulse with Reynolds number 4000 was imposed upon the basic flow to produce a propagating wave. We showed that the reflected waves from the stenosis and the aneurysm are different in their phase, and the wavelength of the reflected waves from the aneurysm is affected by the aneurysm length.
Keywords: Pulse wave propagation, stenosis, aneurysm, reflected waves, fluid-solid interaction, wavelength
DOI: 10.3233/THC-2007-15202
Journal: Technology and Health Care, vol. 15, no. 2, pp. 79-90, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl