Article type: Research Article
Authors: Birken, Thomas; * | Schubert, Jochen | Miekisch, Wolfram | Nöldge-Schomburg, Gabriele
Affiliations: University of Rostock, Department of Anaesthesiology and Intensive Care, Rostock, Germany
Correspondence: [*] Address for correspondence: Thomas Birken MD, University of Rostock, Department of Anaesthesiology and Intensive Care, Schillingallee 35, 18057 Rostock, Germany. Tel.: +49 381 4946430; Fax: +49 381 4946139; E-mail: thomas.birken@medizin.uni-rostock.de.
Abstract: Statement of problem:Different implant geometries present different biomechanical behaviors and in this context, one arising question is how cuneiform implant geometry compares to clinical successful cylindrical threaded implant geometry. Purpose:The purpose of this work was to study stress distribution around cuneiform and cylindrical threaded implant geometries using three-dimensional finite element stress analysis taking the latter as a reference. Material and methods:A model was generated from a computerized tomography of a human edentulous mandible with implants placed in the left first premolar region. The model was supported by the mastication muscles and by temporomandibular joint. A vertical load of 100N was applied at the top of each implant in the direction of their long axes. The mandibular boundary conditions were modeled considering the actual muscle supporting system. Taking muscle forces intensities and directions, balance moment equations were employed to assess the system equilibrium. Cortical and medullary bones were assumed to be homogeneous, isotropic and linearly elastic. Results:The analysis provided results for maximum (S1) and minimum (S2) principal stress and Von Mises (SEQV) stress field. For both geometries, the results showed concentration on one side of the neck, smooth stress distribution along the body and no considerable concentration at the apical area. Conclusion:Results showed similar stress distribution pattern for cuneiform and cylindrical threaded geometries. The stresses profiles along the implants length reproduced their morphology. In both occurred stress concentration at one side of the neck and no body or apical stress concentration.
Keywords: Breath analysis, alveolar gas sampling, capnometry
DOI: 10.3233/THC-2006-14605
Journal: Technology and Health Care, vol. 14, no. 6, pp. 499-506, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl