Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers from the Regensburg Applied Biomechanics Symposium, June 2005
Guest editors: Joachim Hammerx and Michael Nerlichy
Article type: Research Article
Authors: Paróczai, Róbert; * | Kocsis, László
Affiliations: Department of Applied Mechanics, Budapest University of Technology and Economics, Müegyetem rkp. 5., 1111 Budapest, Hungary | [x] Mechanical Engineering Faculty, Laboratory for Materials Technology, University of Applied Science, Regensburg, Germany | [y] University Clinic, Department of Traumatology, Regensburg, Germany
Correspondence: [*] Corresponding author. Tel.: +36 1 463 3678; Fax: +36 1 463 3471; E-mail: paroczai@mm.bme.hu.
Abstract: Recently, there has been great improvement in the field of movement analysis, which is a worldwide tendency. There is a continuous improvement of new methods, combined with traditional ones. In the last few years, we have managed to set up a modern, absolutely up-to-date motion analysis laboratory at the Budapest University of Technology and Economics (BUTE). The primary purpose of this study was to determine usual walking and running parameters as a function of speed and compare our results with the data of other studies. We tested the gait and running characteristics of people at different speeds, measuring the usual parameters of walking and running. On the basis of these measurements, we observed the interrelation of the three main parameters of gait and running (speed, cadence, stride length) and determined the dependence of cadence and stride length on speed as well. The determined energetically optimal walking speed (EOWS) and the usual walking speed (UWS) correlate well with the values in literature. Our measurements were performed on a running corridor, and at the facilities provided by the Biomechanical Laboratory, including an instrumented treadmill connected to the measurement system.
Keywords: Gait analysis, running analysis, kinematic and kinetic parameters, speed
DOI: 10.3233/THC-2006-144-508
Journal: Technology and Health Care, vol. 14, no. 4-5, pp. 251-260, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl