Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Fankhauser, F.a; * | Kwasniewska, S.a | Niederer, P.b | Van der Zypen, E.c
Affiliations: [a] Lindenhofspital, Bern, Switzerland | [b] Institute of Biomedical Engineering, University and ETH Zurich, Switzerland | [c] Institute of Anatomy, University of Bern, Switzerland
Correspondence: [*] Address for correspondence: Professor Franz Fankhauser, MD, Lindenhofspital, Bremgartenstrasse 117, CH-3012 Bern, Switzerland.
Abstract: Supervision is defined by a visual acuity of 20/10 or 20/8 and may be attained by custom-correcting the aberrations of higher order of the human eye. Higher order aberrations are those aberrations which are left in the eye after having corrected lower order aberrations, i.e., defocus (myopia, hypermetropia) regular astigmatism, and which can be corrected by ordinary spectacle lenses or contact lenses. Higher order aberrations are found to a higher or lesser degree in normal or pathological human eyes and in eyes having undergone conventional corneal surgery. According to custom keratorefractive surgery limits, given by the neural visual apparatus and the receptor mosaic, supervision (i.e., 20/10 or even 20/8) may be attained. A number of dedicated sensors have been developed in recent years that are able to detect and measure aberrations of the wave front which is a sensitive procedure for the determination and surgical control of the optical quality of the eye. Not every custom keratorefractive procedure results in supervision, however. This is because not every “normal” eye is able to reach such limits because of its basic design (anatomy or function) and also because keratorefractive procedures neglect the plastic behaviour of the cornea. The plasticity of the central neural system may furthermore interact with corrected or non-corrected visual function.
Keywords: supervision, wave aberration, aberrometry, human eye
DOI: 10.3233/THC-2005-13102
Journal: Technology and Health Care, vol. 13, no. 1, pp. 23-56, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl