Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Córdoba-Díaz, D.; | Córdoba-Díaz, M. | Elorza, B.
Affiliations: Department of Pharmacy and Pharmaceutical Technology, Faculty of Pharmacy, Complutense University of Madrid, Madrid, Spain | Department of Physical Chemistry, Faculty of Pharmacy, Complutense University of Madrid, Madrid, Spain
Note: [] Corresponding author: Prof. Dr. Damián Córdoba-Díaz, Dpto. de Farmacia y Tecnología Farmacéutica, Facultad de Farmacia, Universidad Complutense de Madrid, Pza. de Ramón y Cajal s/n, E-28040, Madrid, España. Tel.: +34 91 394 72 43; Fax: +34 91 394 17 36; E-mail: damianco@farm.ucm.es.
Abstract: Isoniazid, one of the most important drugs for the chemotherapy of tuberculosis, can react with some widely used pharmaceutical excipients, like lactose, leading to the formation of hydrazones. This interaction can dramatically modify the oral bioavailability of the drug, what could lead to a failure of the treatment. Some analytical methods, including techniques like HPLC, can be used to quantify this type of products, but all of them are tedious and time-consuming. In this sense, the aim of the present work is to develop a sensitive, rapid and cheap alternative to other published methods. For this reason, two spectrophotometric methods were developed and validated. In the first one, isoniazid and its lactosyl-hydrazone were measured together. The second one involved a reaction between not bound to lactose isoniazid and 2,3-dichloro-1,4-naphthoquinone. Lactosyl-hydrazone is quantified by comparison of the results obtained from both methods. The linearity is confirmed to be within a range of 1.5–30.0 μg/ml of total isoniazid and 0.5–30.0 μg/ml of “free” isoniazid. Limits of quantification of 1.2 μg/ml and 0.3 μg/ml were obtained for bound and free isoniazid respectively. These results indicated that the here described methods are at least, as sensitive and accurate as the vast majority of the previously published chromatographic methods. This methodology shows a good repeatability (RSD below 2.0%) as well as good accuracy (average recoveries of 100.83% and 99.96% for total and free isoniazid respectively). The results obtained from the assay of isoniazid tablets demonstrated that the proposed method constitutes a clear alternative to chromatographic methods and also to the official titration method. It would be of interest for the routine quality control of oral dosage forms containing isoniazid and lactose and for stability studies.
Keywords: Isoniazid, assay, lactosyl-hydrazone, validation, UV-Vis spectrophotometry, derivatization
DOI: 10.3233/SPE-2009-0385
Journal: Spectroscopy, vol. 23, no. 3-4, pp. 201-208, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl