Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tsai, Jui‐Chen; | Lo, Yu‐Li | Lin, Ching‐Yu; | Sheu, Hamm‐Ming | Lin, Jui‐Che
Affiliations: Institute of Clinical Pharmacy, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan | Department of Pharmacy, Chia‐Nan University of Pharmacy and Science, Tainan Hsien 717, Taiwan | Department of Dermatology, College of Medicine, National Cheng Kung University, 1 University Rd., Tainan 701, Taiwan | Department of Chemical Engineering, College of Engineering, National Cheng Kung University, 1 University Rd., Tainan 701, Taiwan
Note: [] Corresponding author: Tel.: +886 6 2353535, ext. 5687; Fax: +886 6 2373149; E‐mail: jctsai@mail.ncku.edu.tw.
Note: [] Present address: Pfizer Limited, Tamsui, Taiwan.
Abstract: The permeability barrier of skin resides in the stratum corneum, and its properties are mediated by a series of lipid multilayers, enriched in ceramides, cholesterol, and free fatty acids, segregated within the stratum corneum (SC) interstices. SC lipid content is usually determined by gravimetric methods in conjunction with high performance thin layer chromatography, but these methods are time‐consuming and involve hazardous solvents. The objective of the present study was to develop a method of measuring SC lipid content by Fourier transform infrared spectrometry (FTIR) that is fast and requires no solvents. The IR spectra of isolated porcine SC sheets were recorded using a FTIR spectrometer. SC lipid content was determined by gravimetric methods using chloroform–methanol extraction. The peak area of both the CH2 symmetric (2850 cm−1) and asymmetric (2920 cm−1) stretching bands in the IR spectra of progressively solvent‐extracted porcine SC sheets decreased with increasing amount of SC lipids removed. When spectral analysis was performed by curve‐fitting using GRAMS/32 software between 3000 to 2800 cm−1, peak area ratios of CH2 to CH3 asymmetric stretching bands in the IR spectra of 46 isolated porcine SC samples were correlated to SC lipid content (R2=0.90), with the standard error of measurement of 1.91%. The study demonstrated the feasibility of using FTIR technique to rapidly and accurately measure SC lipid content.
Keywords: Stratum corneum, infrared spectrometry, lipid content, quantitation, deconvolution
Journal: Spectroscopy, vol. 18, no. 3, pp. 423-431, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl