Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Otero, Enrique Uceda | Sathaiah, Sokki; | Silveira Jr., Landulfo | Pomerantzeff, Pablo Maria Alberto | Pasqualucci, Carlos Augusto Gonçalves
Affiliations: Biomedical Engineering Division, Institute for Research and Development, University of Vale do Paraíba – UNIVAP, Av. Shishima Hifumi, 2911 Urbanova, ZIP: 12244‐456, São José dos Campos, SP, Brazil | Institute of Heart, University of São Paulo – USP, Av. Dr. Enéas de Carvalho Aguiar, 44 Cerqueira César, ZIP: 05403‐000, São Paulo, SP, Brazil | Department of Cardiovascular Pathology, Faculty of Medicine, University of São Paulo – USP, Av. Dr. Arnaldo, 455, Cerqueira César, ZIP: 01246‐903, São Paulo, SP, Brazil
Note: [] Corresponding author: Sokki Sathaiah, Professor, Group of Diagnosis and Laser Therapy, Biomedical Engineering Division, Instituto de Pesquisa e Desenvolvimento – IP&D, Universidade do Vale do Paraíba – UNIVAP, Av. Shishima Hifumi, Urbanova, 2911, ZIP: 12244‐000, São José dos Campos, SP, Brazil. Tel.: +55 12 3947 1124; Fax: +55 12 3947 1149; E‐mail: sokki@univap.br.
Abstract: Near‐Infrared Raman Spectroscopy (NIRS) has an excellent potential for a rapid, a less invasive and real time diagnosis of various human diseases. The objective of the present study was to apply NIRS for diagnosis of human heart valves and to develop a feasible algorithm to classify the valvular lesions. For Raman studies, a Ti:sapphire laser pumped by an argon laser provided 830 nm excitation. A spectrograph in conjunction with a liquid N2‐cooled CCD detected Raman spectra. A total of 97 fragments of human heart valves were scanned and Raman results were compared with histopathology. Spectra were randomly separated into training and prospective groups. Raman data along with Principal Components Analysis (PCA) and Mahalanobis distance were used to model an algorithm for tissue classification, into two categories: normal (N), and calcified (C) heart valves. It has been found that, for N valves, the algorithm has sensitivities of 95%, 100% and specificities of 100%, 100% for training and prospective groups, respectively. For C valves the algorithm provided sensitivities of 100 and 100% and specificities of 95 and 100% for training and prospective groups, respectively. In conclusion, an algorithm has been developed and successfully applied for NIRS diagnosis of human heart valves with high sensitivities and specificities.
Keywords: Human heart valves, diagnosis, Raman spectroscopy, principal components analysis (PCA)
Journal: Spectroscopy, vol. 18, no. 1, pp. 75-84, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl