Issue title: First International Conference on Biomedical Spectroscopy: From molecules to men, Cardiff, UK, 7–10 July 2002, Part II
Article type: Research Article
Authors: Macnab, Andrew J. | Gagnon, Roy | Gagnon, Faith | Minchinton, Andrew I. | Fryer, Karen H.
Affiliations: Department of Pediatrics, British Columbia's Children's Hospital, University of British Columbia, Vancouver, Canada
Note: [] Corresponding author. Dr. Andrew Macnab, Division of Critical Care, Room 2L5, BC Children's Hospital, 4480 Oak Street, Vancouver, BC, Canada V6H 3V4. Tel.: +1 604 875 3524; Fax: +1 604 875 5136; E‐mail: amacnab@cw.bc.ca.
Abstract: Purpose: Near infrared spectroscopy (NIRS) monitors absolute changes in concentration of chromophores from an unquantified baseline. A change in oxygenation is required to obtain information. Clinically, knowing initial chromophore concentration is desirable. We sought absolute initial concentrations by combining NIRS measurements with simultaneous Eppendorf histograph measurement (absolute values of tissue partial pressure of oxygen (pO2)). Methods: There were 22 trials on 9 occasions in 2 adult volunteers. Following local anaesthetic, the histograph probe was inserted into the forearm muscle and NIRS optodes applied. A sphygmomanometer cuff was inflated over the upper arm to produce ischaemia and hypoxia. Change in pO2 was determined as a percentage of the initial pO2. Change in HbO2 was measured, and the initial HbO2 calculated by assuming the percentage change in HbO2 equaled the percentage change in pO2. Results: Mean percentage change in pO2 was 20.7±9.6. Mean change in HbO2 was 22.4±3.4 μmol/l(tissue). Calculated initial HbO2 was 146.4±108.7 μmol/l(tissue), range 51 to 508 μmol/l(tissue). Correlation (r2) between pO2 and HbO2 was 0.97±0.03. Conclusion: Although changes in pO2 and HbO2 were highly correlated, calculation of initial absolute concentration of HbO2 was not achieved by this method. A reliable method of obtaining absolute concentrations of HbO2 in vivo remains to be found.
Keywords: Near infrared spectroscopy, histography, oxygen consumption, forearm
Journal: Spectroscopy, vol. 17, no. 2-3, pp. 289-295, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl