Article type: Research Article
Authors: Gardi, Adam Z.a | Vogel, Amanda K.a | Dharia, Aastha K.a | Krishnan, Chandramoulia; b; c; d; *
Affiliations: [a] NeuRRo Lab, Department of Physical Medicine and Rehabilitation, Michigan Medicine, Ann Arbor, MI, USA | [b] Michigan Robotics Institute, University of Michigan, Ann Arbor, MI, USA | [c] School of Kinesiology, University of Michigan, Ann Arbor, MI, USA | [d] Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
Correspondence: [*] Corresponding author: Chandramouli Krishnan, PT, PhD, Director, Neuromuscular & Rehabilitation Robotics Laboratory (NeuRRo Lab), Department of Physical Medicine and Rehabilitation, Michigan Medicine, University of Michigan, 325 E Eisenhower Parkway (Suite 3013), Ann Arbor, MI –48108, USA. Tel.: +1 319 321 0117; Fax: +1 734 615 1770; E-mail: mouli@umich.edu.
Abstract: Background:There is a growing concern among the scientific community that the effects of transcranial direct current stimulation (tDCS) are highly variable across studies. The use of different tDCS devices and electrode sizes may contribute to this variability; however, this issue has not been verified experimentally. Objective:To evaluate the effects of tDCS device and electrode size on quadriceps motor cortical excitability. Methods:The effect of tDCS device and electrode size on quadriceps motor cortical excitability was quantified across a range of TMS intensities using a novel evoked torque approach that has been previously shown to be highly reliable. In experiment 1, anodal tDCS-induced excitability changes were measured in twenty individuals using two devices (Empi and Soterix) on two separate days. In experiment 2, anodal tDCS-induced excitability changes were measured in thirty individuals divided into three groups based on the electrode size. A novel Bayesian approach was used in addition to the classical hypothesis testing during data analyses. Results:There were no significant main or interaction effects, indicating that cortical excitability did not differ between different tDCS devices or electrode sizes. The lack of pre-post time effect in both experiments indicated that cortical excitability was minimally affected by anodal tDCS. Bayesian analyses indicated that the null model was more favored than the main or the interaction effects model. Conclusions:Motor cortical excitability was not altered by anodal tDCS and did not differ by devices or electrode sizes used in the study. Future studies should examine if behavioral outcomes are different based on tDCS device or electrode size.
Keywords: Corticospinal excitability, MEP, knee, evoked torque, bayes factor, rehabilitation
DOI: 10.3233/RNN-211210
Journal: Restorative Neurology and Neuroscience, vol. 39, no. 5, pp. 379-391, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl