Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sinnoor, Malaa; * | Janardhan, Shanthi Kaliyilb
Affiliations: [a] Department of Electronics and Communication, Dr. Ambedkar Institute of Technology, Bengaluru, India | [b] Department of Medical Electronics, Dr. Ambedkar Institute of Technology, Bengaluru, India
Correspondence: [*] Corresponding author: Mala Sinnoor, Department of Electronics and Communication, Dr. Ambedkar Institute of Technology, Bengaluru, India. E-mails: malasinnoor.ec@drait.edu.in and malasinnoor.ec@outlook.com.
Abstract: In the present scenario, Electrocardiogram (ECG) is an effective non-invasive clinical tool, which reveals the functionality and rhythm of the heart. The non-stationary nature of ECG signal, noise existence, and heartbeat abnormality makes it difficult for clinicians to diagnose arrhythmia. The most of the existing models concentrate only on classification accuracy. In this manuscript, an automated model is introduced that concentrates on arrhythmia type classification using ECG signals, and also focuses on computational complexity and time. After collecting the signals from the MIT-BIH database, the signal transformation and decomposition are performed by Multiscale Local Polynomial Transform (MLPT) and Ensemble Empirical Mode Decomposition (EEMD). The decomposed ECG signals are given to the feature extraction phase for extracting features. The feature extraction phase includes six techniques: standard deviation, zero crossing rate, mean curve length, Hjorth parameters, mean Teager energy, and log energy entropy. Next, the feature dimensionality reduction and arrhythmia classification are performed utilizing the improved Firefly Optimization Algorithm and autoencoder. The selection of optimal feature vectors by the improved Firefly Optimization Algorithm reduces the computational complexity to linear and consumes computational time of 18.23 seconds. The improved Firefly Optimization Algorithm and autoencoder model achieved 98.96% of accuracy in the arrhythmia type classification, which is higher than the comparative models.
Keywords: Arrhythmia classification, autoencoder, electrocardiogram (ECG), ensemble empirical mode decomposition, firefly optimization algorithm, multiscale local polynomial transform
DOI: 10.3233/MGS-230022
Journal: Multiagent and Grid Systems, vol. 19, no. 1, pp. 43-60, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl