Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hashem, Hishama; b; * | Ibrahim, Adel Ehabb | Elhenawee, Magdaa
Affiliations: [a] Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt | [b] Egyptian International Pharmaceutical Industries Co. “EIPICo”, Tenth of Ramadan City, Egypt
Correspondence: [*] Corresponding author: Dr. Hisham Hashem, Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt and Egyptian International Pharmaceutical Industries Co. “EIPICo”, Tenth of Ramadan City, Egypt. Tel./Fax: +20552303266; E-mail: hisham413@yahoo.com.
Abstract: A simple, rapid and accurate, routine-LC method is described for simultaneous determination of four antihypertensive drugs, hydrochlorothiazide, losartan potassium, valsartan and irbesartan in bulk powders and pharmaceutical preparations. The chromatographic separation of the four pharmaceuticals was achieved on a reversed phase C18 “Intersil® ODS-3” column (5 μm, 4.6×250 mm) using a binary mobile phase of 45% ACN and 55% 50 mM KH2PO4 (pH 4.5) at 1 mL/min flow rate. The detection-wavelength was 210 nm. The total separation time was less than 12 min. The method was validated for system efficiency, linearity, accuracy, precision, limits of detection and quantitation, specificity, stability and robustness. The limits of detection were 0.02, 0.12, 0.14 and 0.01 μg/mL for hydrochlorothiazide, losartan potassium, valsartan and irbesartan, respectively. Linearity ranges were 5–50 μg/mL for hydrochlorothiazide, 10–100 μg/mL for losartan potassium, irbesartan and valsartan. The recovery values of this method were between 97 and 103% and the reproducibility was within 1.67%. Statistical analysis proved that the method enabled reproducible and selective quantification of all four analytes as the bulk drug and in pharmaceutical preparations.
Keywords: HPLC, simultaneous determination, antihypertesives, pharmaceutical preparations
DOI: 10.3233/MGC-160213
Journal: Main Group Chemistry, vol. 15, no. 4, pp. 335-346, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl