Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kano, Torua; * | Koseki, Michihikob
Affiliations: [a] School of Media Science, Tokyo University of Technology, 1404-1, Katakura, Hachioji, Tokyo, Japan | [b] Faculty of Textile Science and Technology, Shinshu University, Tokida, Ueda, Nagano, Japan
Correspondence: [*] Corresponding author: Toru Kano, School of Media Science, Tokyo University of Technology, 1404-1, Katakura, Hachioji, Tokyo 192-0982, Japan. Tel.: +81 90 7607 7114; E-mail: kanohtr@stf.teu.ac.jp.
Abstract: BACKGROUND: Computed tomography (CT) is an established imaging technology primarily used as a non-invasive diagnostic tool that reconstructs axial images. However, significant problems with metal artifacts remain. A metal artifact is a strong radial noise in an image, which makes it difficult to diagnose patients and inspect products containing metal implants. Historically, studies related to metal artifact reduction used projection data, though the data is not typically saved after processing. OBJECTIVE: This study proposes a new metal artifact reduction algorithm that does not require projection data, for new applications and for accurate diagnostic techniques. METHODS: The algorithm utilizes reconstructed images and is based on iterative reconstruction. By reproducing an accurate forward projection on simulation and combining it with an iterative calculation, discrepancies causing metal artifacts are eliminated. RESULTS: Validation was completed with numerical phantom models. Our results indicate that the proposed algorithm effectively reduces metal artifacts, even if numerous complex-shaped metal pieces were embedded in the cross-section. CONCLUSIONS: We developed a novel reconstruction algorithm for metal artifact reduction in CT imaging that only requires reconstructed images and projection conditions. Any historical CT data containing metal artifacts could be improved with this method.
Keywords: Computer tomography (CT), metal artifact, image reconstruction, image processing, iterative reconstruction
DOI: 10.3233/XST-160600
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 6, pp. 901-912, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl