Article type: Research Article
Authors: He, Zhijiea | Qiao, Quanbanga | Li, Juna | Huang, Meipingb | Zhu, Shoupinga | Huang, Liyua; *
Affiliations: [a] School of Life Science and Technology, Xidian University, Xi’an, Shaanxi, PR China | [b] Department of Radiology, Gangdong General Hospital, Guangzhou, Guangdong, PR China
Correspondence: [*] Corresponding author: Liyu Huang, School of Life Science and Technology, Xidian University, Xi’an 710071, PR China. Tel.: +86 18829017263; E-mail: huangly@mail.xidian.edu.cn.
Abstract: BACKGROUND: The CT image reconstruction algorithm based compressed sensing (CS) can be formulated as an optimization problem that minimizes the total-variation (TV) term constrained by the data fidelity and image nonnegativity. There are a lot of solutions to this problem, but the computational efficiency and reconstructed image quality of these methods still need to be improved. OBJECTIVE: To investigate a faster and more accurate mathematical algorithm to settle TV term minimization problem of CT image reconstruction. METHOD: A Nesterov’s algorithm (NESTA) is a fast and accurate algorithm for solving TV minimization problem, which can be ascribed to the use of most notably Nesterov’s smoothing technique and a subtle averaging of sequences of iterates, which has been shown to improve the convergence properties of standard gradient-descent algorithms. In order to demonstrate the superior performance of NESTA on computational efficiency and image quality, a comparison with Simultaneous Algebraic Reconstruction Technique-TV (SART-TV) and Split-Bregman (SpBr) algorithm is made using a digital phantom study and two physical phantom studies from highly undersampled projection measurements. RESULTS: With only 25% of conventional full-scan dose and, NESTA method reduces the average CT number error from 51.76HU to 9.98HU on Shepp-Logan phantom and reduces the average CT number error from 50.13HU to 0.32HU on Catphan 600 phantom. On an anthropomorphic head phantom, the average CT number error is reduced from 84.21HU to 1.01HU in the central uniform area. CONCLUSIONS: To the best of our knowledge this is the first work that apply the NESTA method into CT reconstruction based CS. Research shows that this method is of great potential, further studies and optimization are necessary.
Keywords: Compressed sensing, total variation, NESTA, CT
DOI: 10.3233/XST-160597
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 6, pp. 865-874, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl