Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Niu, Shanzhoua; b | Li, Shuoa | Huang, Shuyana | Liang, Lijinga | Tang, Sizhoua | Wang, Tinghuaa | Yu, Gaohangc | Niu, Tianyed | Wang, Jinge; * | Ma, Jianhuaf; *
Affiliations: [a] School of Mathematics and Computer Science, Gannan Normal University, Ganzhou, China | [b] Ganzhou Key Laboratory of Computational Imaging, Gannan Normal University, Ganzhou, China | [c] School of Science, Hangzhou Dianzi University, Hangzhou, China | [d] Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China | [e] Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA | [f] School of Biomedical Engineering, Southern Medical University, Guangzhou, China
Correspondence: [*] Corresponding authors: *Jing Wang; E-mail: jing.wang@utsouthwestern.edu and Jianhua Ma; E-mail: jhma@smu.edu.cn.
Abstract: BACKGROUND:Dynamic cerebral perfusion CT (DCPCT) can provide valuable insight into cerebral hemodynamics by visualizing changes in blood within the brain. However, the associated high radiation dose of the standard DCPCT scanning protocol has been a great concern for the patient and radiation physics. Minimizing the x-ray exposure to patients has been a major effort in the DCPCT examination. A simple and cost-effective approach to achieve low-dose DCPCT imaging is to lower the x-ray tube current in data acquisition. However, the image quality of low-dose DCPCT will be degraded because of the excessive quantum noise. OBJECTIVE:To obtain high-quality DCPCT images, we present a statistical iterative reconstruction (SIR) algorithm based on penalized weighted least squares (PWLS) using adaptive prior image constrained total generalized variation (APICTGV) regularization (PWLS-APICTGV). METHODS:APICTGV regularization uses the precontrast scanned high-quality CT image as an adaptive structural prior for low-dose PWLS reconstruction. Thus, the image quality of low-dose DCPCT is improved while essential features of targe image are well preserved. An alternating optimization algorithm is developed to solve the cost function of the PWLS-APICTGV reconstruction. RESULTS:PWLS-APICTGV algorithm was evaluated using a digital brain perfusion phantom and patient data. Compared to other competing algorithms, the PWLS-APICTGV algorithm shows better noise reduction and structural details preservation. Furthermore, the PWLS-APICTGV algorithm can generate more accurate cerebral blood flow (CBF) map than that of other reconstruction methods. CONCLUSIONS:PWLS-APICTGV algorithm can significantly suppress noise while preserving the important features of the reconstructed DCPCT image, thus achieving a great improvement in low-dose DCPCT imaging.
Keywords: DCPCT reconstruction, PWLS, total generalized variation, prior image
DOI: 10.3233/XST-240104
Journal: Journal of X-Ray Science and Technology, vol. Pre-press, no. Pre-press, pp. 1-19, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl