Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cortez, Jarroda | Romero, Ignaciob | Ngo, Jasonb | Azam, Md Sayed Tanveere | Niu, Chuange | Almeida-da-Silva, Cássio Luiz Coutinhoc | Cabido, Leticia Ferreirad | Ojcius, David M.c | Chin, Wei-Chunb | Wang, Gee | Li, Changqinga; f; *
Affiliations: [a] Quantitative and Systems Biology, University of California, Merced, CA, USA | [b] Department of Bioengineering, University of California, Merced, CA, USA | [c] Department of Biomedical Sciences, University of the Pacific, San Francisco, CA, USA | [d] Department of Oral and Maxillofacial Surgery, University of the Pacific, San Francisco, CA, USA | [e] Department of Biomedical Engineering, Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA | [f] Department of Electrical Engineering, University of California, Merced, CA, USA
Correspondence: [*] Corresponding authors: Changqing Li, Quantitative and Systems Biology, University of California, Merced, CA 95343, USA. E-mail: cli32@ucmerced.edu.
Abstract: BACKGROUND:Periodontal disease affects over 50% of the global population and is characterized by gingivitis as the initial sign. One dental health issue that may contribute to the development of periodontal disease is foreign body gingivitis (FBG), which can result from exposure to some kinds of foreign metal particles from dental products or food. OBJECTIVE:We design a novel, portable, affordable, multispectral X-ray and fluorescence optical microscopic imaging system dedicated to detecting and differentiating metal oxide particles in dental pathological tissues. A novel denoising algorithm is applied. We verify the feasibility and optimize the performance of the imaging system with numerical simulations. METHODS: The designed imaging system has a focused X-ray tube with tunable energy spectra and thin scintillator coupled with an optical microscope as detector. A simulated soft tissue phantom is embedded with 2-micron thick metal oxide discs as the imaged object. GATE software is used to optimize the systematic parameters such as energy bandwidth and X-ray photon number. We have also applied a novel denoising method, Noise2Sim with a two-layer UNet structure, to improve the simulated image quality. RESULTS: The use of an X-ray source operating with an energy bandwidth of 5 keV, X-ray photon number of 108, and an X-ray detector with a 0.5 micrometer pixel size in a 100 by 100-pixel array allowed for the detection of particles as small as 0.5 micrometer. With the Noise2Sim algorithm, the CNR has improved substantially. A typical example is that the Aluminum (Al) target’s CNR is improved from 6.78 to 9.72 for the case of 108 X-ray photons with the Chromium (Cr) source of 5 keV bandwidth. CONCLUSIONS: Different metal oxide particles were differentiated using Contrast-to-Noise ratio (CNR) by utilizing four different X-ray spectra.
Keywords: X-ray imaging, Monte Carlo, GATE, Denoise
DOI: 10.3233/XST-230175
Journal: Journal of X-Ray Science and Technology, vol. 32, no. 1, pp. 87-103, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl