Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ma, Junmin; *
Affiliations: Department of Radiology, General Hospital of Tisco (The Sixth Hospital of Shanxi Medical University), Taiyuan, Shanxi, China
Correspondence: [*] Corresponding author: Junmin Ma, Department of Radiology, General Hospital of Tisco (The Sixth Hospital of Shanxi Medical University), No. 7 Yingxin Road, Jiancaoping District, Taiyuan City, Shanxi Province, China. Tel.: +86 0351 2132998; E-mail: ma_junmin@126.com.
Abstract: OBJECTIVE:To explore the application value of digital tungsten-molybdenum double target three-dimensional positioning indwelling guide wire and guided surgical resection biopsy in the diagnosis of breast microcalcification. METHODS:A retrospective analysis of 168 patients with negative clinical palpation and molybdenum target X-ray examination found breast abnormalities were equally divided into two groups according to different surgical positioning methods. The control and observation group underwent gross positioning biopsy and digital tungsten-molybdenum dual-target three-dimensional positioning indwelling guide wire to guide surgical resection biopsy, respectively. The results of molybdenum target X-ray examination and the success rate of one-time complete resection of the lesions were compared between the two groups, and the corresponding relationship between the pathological diagnosis results of the lesions after surgical resection and the performance of mammography in the observation group was compared. RESULTS:There was no significant difference in age and molybdenum target X-ray examination results between the two groups (P > 0.05). General information is comparable; the success rate of one-time complete resection of lesions in the observation group was significantly higher than that in the control group (95.2% vs 78.6%, P = 0.024). There were 34 cases of malignant lesions in the observation group, accounting for 40.5% (34/84), including 11 cases of invasive ductal carcinoma (64.7%), 50 cases of benign lesions, accounting for 59.5% (50/84), including 16 cases of breast lobular hyperplasia (32%), 18 cases of breast cystic hyperplasia (36%). CONCLUSION:In diagnosis of breast microcalcifications, surgical resection biopsy guided using digital tungsten-molybdenum double target three-dimensional positioning indwelling guide wire achieves high success rate and has advantages of high safety and accurate diagnosis. Thus, it has potential to play a greater role in early diagnosis of breast cancer and is worthy of clinical application.
Keywords: Tungsten and molybdenum, microcalcification of breast, Three-dimensional stereoscopic, guide wire, target X-ray
DOI: 10.3233/XST-230039
Journal: Journal of X-Ray Science and Technology, vol. 31, no. 4, pp. 853-864, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl