Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Li, Tingtinga; 1 | Liu, Yub; 1 | Guo, Jiuhongb | Wang, Yuanjuna; *
Affiliations: [a] Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China | [b] Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School ofMedicine, Shanghai 200011, China
Correspondence: [*] Correspondence to: Yuanjun Wang, Institute of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China E-mail: yjusst@126.com.
Note: [1] These authors contributed equally.
Abstract: PURPOSE:To investigate the value of a CT-based radiomics model in identification of Crohn’s disease (CD) active phase and remission phase. METHODS:CT images of 101 patients diagnosed with CD were retrospectively collected, which included 60 patients in active phase and 41 patients in remission phase. These patients were randomly divided into training group and test group at a ratio of 7 : 3. First, the lesion areas were manually delineated by the physician. Meanwhile, radiomics features were extracted from each lesion. Next, the features were selected by t-test and the least absolute shrinkage and selection operator regression algorithm. Then, several machine learning models including random forest (RF), extreme gradient boosting (XGBoost), support vector machine (SVM), logistic regression (LR) and K-nearest neighbor (KNN) algorithms were used to construct CD activity classification models respectively. Finally, the soft-voting mechanism was used to integrate algorithms with better effects to perform two classifications of data, and the receiver operating characteristic curves were applied to evaluate the diagnostic value of the models. RESULTS:Both on the training set and the test set, AUC of the five machine learning classification models reached 0.85 or more. The ensemble soft-voting classifier obtained by using the combination of SVM, LR and KNN could better distinguish active CD from CD remission. For the test set, AUC was 0.938, and accuracy, sensitivity, and specificity were 0.903, 0.911, and 0.892, respectively. CONCLUSION:This study demonstrated that the established radiomics model could objectively and effectively diagnose CD activity. The integrated approach has better diagnostic performance.
Keywords: Crohn’s disease, activity, radiomics, machine learning, ensemble algorithm
DOI: 10.3233/XST-221224
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 6, pp. 1155-1168, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl