Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Durmus, Ismail Faruka; b; * | Okumus, Aysea
Affiliations: [a] Department of Radiation Oncology, Nisantasi University, Istanbul, Turkey | [b] Department of Radiation Oncology, Yeni Yuzyil University Gaziosmanpasa Hospital, Istanbul, Turkey
Correspondence: [*] Corresponding author: Ismail Faruk Durmus, Department of Radiation Oncology, Yeni Yuzyil University Gaziosmanpasa Hospital, Istanbul, Turkey. Tel.: +90 505 9004664; Fax: +90 212 6153849/2331; E-mail: ifarukdurmus@gmail.com.; ORCID: 0000000165118104.
Abstract: OBJECTIVE:To compare dosimetric and radiobiological terms of modified dynamic conformal arc therapy (mDCAT) and volumetric modulated arc therapy (VMAT) techniques using different flattening-filter free (FFF) energies in patients with single adrenal metastasis. METHODS:In this study, plans were prepared for 10 patients drawing on the mDCAT and VMAT techniques with 6MV-FFF and 10MV-FFF energies. Target volume doses, biological effective doses (BED), quality indices, Monitor Unit (MU), number of segments, beam-on time and critical organ doses were compared in the plans. RESULTS:Plans with the significantly lower gradient index (GI) and conformity index (CI) values were obtained with 6MV-FFF energy VMAT planning (p < 0.05). The higher values were obtained for dose to 95% of internal target volume (ITVD95), ITVD95-BED10 with 10MV-FFF energy VMAT planning, whereas lower results were obtained for high dose spillage (HDS%) values (p < 0,05). With 10MV-FFF energy, HDS% values were 21.1% lower in VMAT plans and 5.6% lower in mDCAT plans compared to 6MV-FFF energy. Plans with approximately 50% fewer segments were obtained in mDCAT plans than VMAT plans (p < 0,05). Beam-on time values with mDCAT was 1.84 times lower when 6MV-FFF energies were analyzed, and 2.11 times lower when 10MV-FFF was analyzed (p < 0,05). Additionally, when 6MV-FFF and 10MV-FFF energies were examined, MU values with mDCAT were 2.1 and 2.5 times lower (p < 0,05). In general, the smaller the target volume size, the greater the differences between MU and beam-on time values mDCAT and VMAT. CONCLUSIONS:The study results implied that VMAT enabled to offer significantly more conformal SBRT plans with steeper dose fall-off beyond the target volume for single adrenal metastasis than the mDCAT, which attained at the cost of significantly higher MU and beam-on times. Especially with 10MV-FFF energy mDCAT plans, low-dose-bath zones can be reduced, and shorter-term treatments can be implemented with large segments. In adrenal gland SBRT, higher effective doses can be achieved with the right energy and technique, critical organ doses can be reduced, thus increasing the possibility of local control of the tumor with low toxicity.
Keywords: Adrenal gland SBRT, mDCAT, VMAT, FFF
DOI: 10.3233/XST-221192
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 5, pp. 1023-1032, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl