Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hu, Dongcai | Zhou, Zheng | Wang, Jianxin | Xiao, Dexin | Zhou, Kui | Li, Peng | Li, Shigen | Shan, Lijun | Wang, Hanbin | Liu, Yu | Shen, Xuming | Lao, Chenglong | Luo, Xing | He, Tianhui | Zhang, Peng | Yan, Longgang | Liu, Jie | Ding, Yushou | Cai, Zhe | Li, Lei | Zhang, Chengxin | Liu, Qinghua | Li, Jing | Wang, Yuan | Yang, Xingfan | Li, Ming | Wu, Dai; * | Chen, Menxue | Zhao, Jianheng; *
Affiliations: Institute of Applied Electronics, China Academy of Engineering Physics (CAEP), Mianyang, China
Correspondence: [*] Corresponding authors. Dai Wu and Jianheng Zhao, Institute of Applied Electronics, China Academy of Engineering Physics (CAEP), Mianyang, 621900, China. E-mail: wudai04@163.com (Dai Wu) and E-mail: jianh_zhao@caep.cn (Jianheng Zhao).
Abstract: High-energy, high-dose, microfocus X-ray computed tomography (HHM CT) is one of the most effective methods for high-resolution X-ray radiography inspection of high-density samples with fine structures. Minimizing the effective focal spot size of the X-ray source can significantly improve the spatial resolution and the quality of the sample images, which is critical and important for the performance of HHM CT. The objective of this study is to present a 9 MeV HHM CT prototype based on a high-average-current photo-injector in which X-rays with about 70μm focal spot size are produced via using tightly focused electron beams with 65/66μm beam size to hit an optimized tungsten target. In digital radiography (DR) experiment using this HHM CT, clear imaging of a standard 0.1 mm lead DR resolution phantom reveals a resolution of 6 lp/mm (line pairs per mm), while a 5 lp/mm resolution is obtained in CT mode using another resolution phantom made of 10 mm ferrum. Moreover, comparing with the common CT systems, a better turbine blade prototype image was obtained with this HHM CT system, which also indicates the promising application potentials of HHM CT in non-destructive inspection or testing for high-density fine-structure samples.
Keywords: Digital radiography (DR), Microfocus X-ray computed tomography (CT), non-destructive inspection, X-ray source, X-ray focal spot
DOI: 10.3233/XST-210960
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 1, pp. 1-12, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl