Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhu, Yanana; * | Pi, Zhiana | Zhou, Hepinga | Li, Zhengjuna | Lei, Faqinga | Hui, Jianjunb | Zhang, Ximenga | Xie, Juanpingc | Liang, Yukuna
Affiliations: [a] Medical Imaging Centre, Affiliated Hospital of Ankang University (Ankang Central Hospital), Ankang, China | [b] Emergency Department, Affiliated Hospital of Ankang University (Ankang Central Hospital), Ankang, China | [c] School of Medicine, Ankang University, Ankang, China
Correspondence: [*] Corresponding author: Yanan Zhu, MD, Medical Imaging Centre, Affiliated hospital of Ankang University (Ankang Central Hospital), Ankang 725000, China. Tel.: +86 09153284340; Fax:+86 09153284363; E-mail: zhuyanan1977@163.com.
Abstract: OBJECTIVE:To demonstrate the ability of achieving low dose and high-quality head CT images for children with acute head trauma using 100 kVp and adaptive statistical iterative reconstruction (ASIR-V) algorithm in single rotation on a 16 cm wide-detector system. MATERIALS AND METHODS:We retrospectively analyzed the CT dose index (CTDI) and image quality of 104 children aged 0–6 years with acute head trauma (1 hour –3 days) in two groups: Group 1(n = 50) on a 256-row CT with single rotation at a reduced-dose of 100 kVp/240 mA and reconstructed using ASIR-V at 70%level; Group 2(n = 54) on a 64-row CT with multiple rotations at a standard dose of 120 kVp/ 180mA and reconstructed using a conventional filtered back-projection (FBP). Both groups used the 0.5 s/r axial scan mode. CT dose index (CTDI) and quantitative image quality measurements were compared using the Student t test; qualitative image quality comparison was carried out using Mann-Whitney rank test and the inter-reviewer agreement was evaluated using Kappa test. RESULTS:The exposure time was 0.5 s for Group 1 and 3.27±0.29 s for Group 2. The CTDI in Group 1 was 9.74±0.86mGy, 36.38%lower than the 15.31mGy in Group 2 (p < 0.001). Group 1 and Group 2 had similar artifact index (2.06±1.06 vs. 2.37±1.18) in the cerebellar hemispheres, and similar contrast-to-noise ratio (2.32±0.83 vs. 1.69±0.68), (1.47±0.72 vs. 1.10±0.43) respectively for cerebellum and thalamus (p > 0.05). Image quality was acceptable for diagnosis, and motion artifacts were reduced in Group 1 (p < 0.001). CONCLUSION:Single rotation CT with 100 kVp and 70%ASIR-V on 16 cm wide-detector CT reduces radiation dose and motion artifacts for children with acute head trauma without compromising diagnostic quality as compared with standard dose protocol. Thus, it provides a novel imaging method in management of pediatric acute head trauma.
Keywords: Head trauma, adaptive statistical iterative reconstruction, children, wide-detector computed tomography, radiation dose reduction, single rotation
DOI: 10.3233/XST-210856
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 3, pp. 517-527, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl