Article type: Research Article
Authors: Shen, Wentinga; b | Chen, Yanga | Qian, Wena | Liu, Wangyana | Zhu, Yinsua | Xu, Yia | Zhu, Xiaomeia; *
Affiliations: [a] Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Guangzhou Road, Nanjing, Jiangsu, China | [b] Department of Radiology, Liyang people’s hospital, Jianshe West Road, Liyang, Jiangsu, China
Correspondence: [*] Corresponding author: Xiaomei Zhu, MD, PhD, Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd., Nanjing, China. Tel.: +86 13770346260 –Ext: 210029; E-mail: xiaomeizhu@njmu.edu.cn.
Abstract: BACKGROUND:Accuracy of CT-derived fractional flow reserve depends on good image quality. Thus, improving image quality during coronary CT angiography (CCTA) is important. OBJECTIVE:To investigate impact of respiratory motion artifact on coronary image quality focusing on vessel diameter and territory during one beat CCTA by a 256-row detector. METHODS:We retrospectively reviewed patients who underwent CCTA under free-breathing (n = 100) and breath-holding (n = 100), respectively. Coronary image quality is defined as 4-1 from excellent to poor (non-diagnostic) and respiratory motion artifact severity is also scored on a 4-point scale from no artifact to severe artifact. Coronary image quality and respiratory motion artifact severity of all images were evaluated by two radiologists independently. RESULTS:Compared with free-breathing group, the image qualities are significantly higher in per-segment, per-vessel and per-patient levels (P < 0.001) and proportion of segments with excellent image quality also improves significantly (73.6% vs 60.1%, P < 0.001) in breath-holding group. The image quality improvement occurs in medium-sized coronary arterial segments. Coronary image quality improves with respiratory motion artifacts decreasing in both groups, respectively. CONCLUSION:During one heartbeat CCTA, breath-holding is still recommended to improve coronary image quality due to improvement of the image quality in the medium-sized coronary arteries.
Keywords: Motion artifacts, computed tomography angiography, coronary angiography, breath holding
DOI: 10.3233/XST-200812
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 2, pp. 287-296, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl