Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hu, Juna; b; * | Huang, Xiaolingb
Affiliations: [a] Department of Ultrasound, Chonggang General Hospital, Chongqing, China | [b] Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
Correspondence: [*] Corresponding author: Jun Hu, Department of Ultrasound, Chonggang General Hospital, No. 1, Dayan Sancun, Dadukou District, Chongqing 400081, China. Tel./Fax: +86 23 6884 6840; E-mail: cqmudoctorhujun@163.com.
Abstract: OBJECTIVE:To evaluate the diagnostic value of ultrasonography and mammography for plasma cell mastitis. METHODS:The ultrasonographic and mammographic images of 111 women with histopathologically confirmed plasma cell mastitis were retrospectively analyzed. The diagnostic accuracy of the two imaging methods was compared. RESULTS:Ultrasonography identified 91 out of 111 (82.0%) patients with plasma cell mastitis, while the other twenty (18.0%) patients were misdiagnosed. Mammography identified 83 (74.8%) out of 111 patients with plasma cell mastitis. Nineteen (17.1%) patients were misdiagnosed. There was no significant difference between the diagnostic accuracy of using two imaging tests (P = 0.127). Mammography clouds identified 11 out of 20 patients who were not diagnosed by ultrasonography. Meanwhile, 19 of the 28 cases misdiagnosed with mammography were correctly identified by ultrasonography. Overall, 91.9% (102/111) of the patients were identified by the combination of ultrasonography and mammography, which yielded statistically significant higher accuracy than using each single test only (P < 0.05). CONCLUSIONS:In diagnosis of plasma cell mastitis, high-frequency ultrasonography and mammography should be combined to improve the diagnostic accuracy.
Keywords: Mastitis, plasma cell, Doppler ultrasound, X-ray, breast
DOI: 10.3233/XST-190607
Journal: Journal of X-Ray Science and Technology, vol. 28, no. 3, pp. 555-561, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl