Affiliations: [a] School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China | [b] Department of Biomedical Engineering, University of Florida, Gainesville, Florida, USA | [c] Center for Information in Medicine, University of Electronic Science and Technology of China Chengdu, China | [d] Department of Medical Engineering, University of South Florida, Tampa, Florida, USA
Correspondence: [*] Address for correspondence: Huabei Jiang, ENB 343J, Department of Medical Engineering, University of South Florida, Tampa, Florida, USA; Tel: 813-974-5253; E-mail: hjiang1@usf.edu.
Abstract: BACKGROUND:Microwave-induced thermoacoustic tomography (TAT) has potential for detecting germinal matrix hemorrhage (GMH). However, it has not been demonstrated in vivo. OBJECTIVE:To demonstrate the feasibility of TAT for in vivo detecting GMH by using neonatal mouse. METHODS:A cylindrical-scanning TAT system was developed with optimized microwave irradiation and ultrasound detection for neonatal mouse imaging. Neonatal mice were used to develop GMH model by injection of autologous blood into the periventricular region. After TAT experiments, the animals were sacrificed, frozen and excised to validate the TAT findings. The detailed comparative analyses of the TAT images and corresponding photographs of the excised brain tissues were conducted. RESULTS:Satisfactory matches are identified between the TAT images and corresponding histological sections, in terms of the shape and size of the brain tissues. Some organs and tissues were also identified. Particularly, comparing to the corresponding histological sections, using TAT enables to more accurately detect the hematoma region at different depths in the neonatal mouse brain. CONCLUSIONS:This study demonstrates for the first time that TAT can detect GMH in neonatal mouse cerebrum in vivo. This represents the first important step towards the in vivo diagnosis and grading of hemorrhage in the infant human brain.
Keywords: Thermoacoustic tomography, neonatal mouse, hemorrhage, germinal matrix hemorrhage, tissue dielectric properties
DOI: 10.3233/XST-190599
Journal: Journal of X-Ray Science and Technology, vol. 28, no. 1, pp. 83-93, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl