Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wang, Yua; b | Wu, Boa; b | Zhang, Nana; b; * | Liu, Jiabaoc; * | Ren, Feid | Zhao, Liqinc
Affiliations: [a] School of Biomedical Engineering, Capital Medical University, Beijing, China | [b] Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China | [c] Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China | [d] Institute of Computing Technology, Chinese Academy of Sciences, Beijing, China
Correspondence: [*] Corresponding authors: Nan Zhang, Email: zhangnan@ccmu.edu.cn and Jiabao Liu, E-mail: liujiabao0811@163.com.
Abstract: BACKGROUND AND OBJECTIVE:Since CAD (Computer Aided Diagnosis) system can make it easier and more efficient to interpret CT (Computer Tomography) images, it has gained much attention and developed rapidly in recent years. This article reviews recent CAD techniques for pulmonary nodule detection and diagnosis in CT Images. METHODS:CAD systems can be classified into computer-aided detection (CADe) and computer-aided diagnosis (CADx) systems. This review reports recent researches of both systems, including the database, technique, innovation and experimental results of each work. Multi-task CAD systems, which can handle segmentation, false positive reduction, malignancy prediction and other tasks at the same time. The commercial CAD systems are also briefly introduced. RESULTS:We have found that deep learning based CAD is the mainstream of current research. The reported sensitivity of deep learning based CADe systems ranged between 80.06% and 94.1% with an average 4.3 false-positive (FP) per scan when using LIDC-IDRI dataset, and between 94.4% and 97.9% with an average 4 FP/scan when using LUNA16 dataset, respectively. The overall accuracy of deep learning based CADx systems ranged between 86.84% and 92.3% with an average AUC of 0.956 reported when using LIDC-IDRI dataset. CONCLUSIONS:We summarized the current tendency and limitations as well as future challenges in this field. The development of CAD needs to meet the rigid clinical requirements, such as high accuracy, strong robustness, high efficiency, fine-grained analysis and classification, and to provide practical clinical functions. This review provides helpful information for both engineering researchers and radiologists to learn the latest development of CAD systems.
Keywords: Pulmonary nodules, computer-aided detection (CADe), computer-aided diagnosis (CADx), multi-task CAD
DOI: 10.3233/XST-190581
Journal: Journal of X-Ray Science and Technology, vol. 28, no. 1, pp. 1-16, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl