Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cheng, You-Gena; 1 | Sun, Zong-Qiongb; 1 | Zhang, Hong-Xiaa | Mao, Guo-Quna; *
Affiliations: [a] Department of Radiology, Tongde Hospital of Zhejiang Province, Hangzhou, Zhejiang, China | [b] Department of Radiology, Affiliated Hospital of Jiangnan University, The Forth People’s Hospital of Wuxi City, Wuxi, Jiangsu, China
Correspondence: [*] Corresponding author: Guo-Qun Mao, Department of Radiology, Tongde Hospital of Zhejiang Province, Hangzhou, Zhejiang, 310012, China. Tel.: +86 15312238218; E-mail: maoguoqun123@163.com.
Note: [1] You-Gen Cheng and Zong-Qiong Sun contributed equally to this work.
Abstract: PURPOSE:To explore the characteristics of breast cancer and breast fibroadenoma using low-dose computed tomography perfusion imaging (LDCTPI) including specific perfusion parameter values, and seek the potential clinical applications in cancer prognosis assessment. MATERIALS AND METHODS:Fifty patients including 30 diagnosed with breast cancer and 20 with breast fibroadenoma, as well as 15 control subjects with normal breasts were studied prospectively using LDCTPI examinations. The acquired volumetric imaging data were used for calculation, mapping and analysis by using a body tumor perfusion protocol in the CT perfusion software to measure 4 parameters: blood flow (BF), blood volume (BV), mean transit time (MTT), and the permeability surface (PS) area product. Statistical data analysis was then performed to distinguish the difference of the 4 parameter values among normal control, breast cancer and breast fibroadenoma cases. RESULTS:The mean perfusion values of 15 normal controls were as follows: BF, 20.03±4.08 mL/100 g/min; BV, 4.53±0.95 mL/100 g; MTT, 5.90±0.82 s; and PS, 9.25±1.18 mL/100 g/min. The mean perfusion values of 30 cancer patients were as follows: BF, 56.67±6.59 mL/100 g/min; BV, 5.82±0.68 mL/100 g; MTT, 6.01±0.82 s; and PS, 24.95±5.05 mL/100 g/min. The mean perfusion values of 20 patients with breast fibroadenoma were as follows: BF, 46.24±6.65 mL/100 g/min; BV, 5.07±0.73 mL/100 g; MTT, 7.51±0.62 s; and PS, 16.73±6.48 mL/100 g/min. Comparing the 3 groups, differences were all statistically significant for BF, BV, MTT and PS values (p < 0.05, respectively); The BF, BV, PS values were highest in group of cancer patients, while the MTT value was highest in group of patients diagnosed with breast fibroadenoma. CONCLUSION:Breast CT perfusion imaging is a promising functional imaging technology in breast cancer diagnosis, which can provide valuable quantitative imaging markers to assist evaluation of breast tumors.
Keywords: Breast cancer, breast fibroadenoma, low dose, low-dose CT perfusion imaging, quantitative imaging markers, evaluation of tumor characteristics.
DOI: 10.3233/XST-18377
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 4, pp. 681-690, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl