Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Yuana | Zhang, Liyia; b | Sun, Yunshanb; *
Affiliations: [a] School of Electrical and Information Engineering, Tianjin University, Tianjin, China | [b] School of Information Engineering, Tianjin University of Commerce, Tianjin, China
Correspondence: [*] Corresponding author: Dr. Yunshan Sun, Ph.D., School of Information Engineering, Tianjin University of Commerce, Tianjin, China. Tel./Fax: +86 022 26675771; E-mail: sunyunshan@tjcu.edu.cn.
Abstract: BACKGROUND:In computed tomography (CT), a patient motion would result in degraded spatial resolution and image artifacts. OBJECTIVE:To eliminate motion artifacts, this study presents a method to estimate the motion parameters from sinograms based on extended difference function. METHODS:Based on our previous work, we first divide the projection data into two parts according to view angles and take Radon transform. Then, we calculate the extended difference functions and search for the minimum points. The relative displacements can be determined by the minimum points, and the motion can be estimated by the relationships between the relative displacements and motion parameters. Finally, we introduce the estimated parameters into the reconstruction process to compensate for the motion effects. RESULTS:The simulation results show that the running times can reduce by about 30% than our previous work. In phantom experiments, the relative mean rotation excursion (RMRE) and relative mean translation excursion (RMTE) of the new method are lower than the conventional Helgason–Ludwig consistency condition (HLCC) based method and comparable to our previous work. Compare with the HLCC method, the root mean square error (RMSE) of the new method also reduces, while the Pearson correlation coefficient (CC) and mean structural similarity index (MSSIM) increase. CONCLUSIONS:The proposed new method yields the improved performance on accuracy of motion estimation with higher computational efficiency, and thus it can produce high-quality images.
Keywords: Computed Tomography (CT), extended difference function, fan-beam, motion estimation, motion artifacts
DOI: 10.3233/XST-180442
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 2, pp. 273-285, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl