Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Shihea | Fu, Qingb | Yu, Hualonga | Zhang, Chuanyua | Yang, Qinga | Hu, Yabina | Xu, Wenjiana; *
Affiliations: [a] Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, China | [b] Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, China
Correspondence: [*] Corresponding author: Wenjian Xu, Department of Radiology, The Affiliated Hospital of Qingdao University, No.16 Jiangsu Road, Shinan District, Qingdao 266000, P.R. China. Tel.: +86 15192678076; Fax: +86 0532 82913018; E-mail: xuwenjian6688@sina.com.
Abstract: BACKGROUND:640-slice coronary CT angiography is becoming an accurate and reliable method of diagnosing coronary heart disease. However, how to reduce the radiation dosage while ensuring the clinically acceptable image quality remains a quite challenging issue. OBJECTIVE:To evaluate the effect of low tube voltage on radiation dosage under 640-slice coronary CT angiography (CCTA). METHODS:Four hundred patients (236 males, 164 females) with coronary heart disease and underwent CCTA using DCVT were classified into A1 (tube voltage: 120 kV; exposure phase window: 30–80%), B1 (120 kV; 70–80%), A2 (100 kV; 30–80%) and B2 group (100 kV; 70–80%), respectively. Image qualities and effective dose (ED) were assessed and compared. RESULTS:No significant differences were observed among the groups in terms of age, height, weight and body mass index (BMI) (P > 0.05). ED were significantly lower in 100 kV group (P < 0.05). CT values of coronary artery in 100 kV groups were 13.5% and 17.3% higher than 120 kV group. ED in B1 group were 64.5% and 67.0% lower than A1 group. ED in B2 group were 65.4% and 65.2% lower than A2 group. CONCLUSION:When using a 640-slice CCTA prospective ECG-gating scanning mode, it is preferable to use a 100 kV tube voltage setting because compared to 120 kV tube voltage protocol, it seems to significantly decrease the mean effective radiation dose, without significantly lowering both the subjective and objective image quality.
Keywords: 640-slices CT, coronary CT angiography, radiation dosage, tube voltage, image quality
DOI: 10.3233/XST-17332
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 3, pp. 463-471, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl