Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Yan; | Ma, Jianhua | Zhang, Hao; | Wang, Jing | Liang, Zhengrong;
Affiliations: Department of Radiology, State University of New York, Stony Brook, NY, USA | Department of Electrical and Computer Engineering, State University of New York, Stony Brook, NY, USA | School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China | Department of Radiology and Biomedical Engineering, State University of New York, Stony Brook, NY, USA | Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA
Note: [] Corresponding author: Zhengrong Liang, Departments of Radiology and Biomedical Engineering, State University of New York, Stony Brook, NY, USA. Tel.: +1 631 444 7837; Fax: +1 631 444 6450; E-mail: Jerome@mil.sunysb.edu
Abstract: BACKGROUND: The negative effects of X-ray exposure, such as inducing genetic and cancerous diseases, has arisen more attentions. OBJECTIVE: This paper aims to investigate a penalized re-weighted least-square (PRWLS) strategy for low-mAs X-ray computed tomography image reconstruction by incorporating an adaptive weighted total variation (AwTV) penalty term and a noise variance model of projection data. METHODS: An AwTV penalty is introduced in the objective function by considering both piecewise constant property and local nearby intensity similarity of the desired image. Furthermore, the weight of data fidelity term in the objective function is determined by our recent study on modeling variance estimation of projection data in the presence of electronic background noise. RESULTS: The presented AwTV-PRWLS algorithm can achieve the highest full-width-at-half-maximum (FWHM) measurement, for data conditions of (1) full-view 10 mA acquisition and (2) sparse-view 80 mA acquisition. In comparison between the AwTV/TV-PRWLS strategies and the previous reported AwTV/TV-projection onto convex sets (AwTV/TV-POCS) approaches, the former can gain in terms of FWHM for data condition (1), but cannot gain for the data condition (2). CONCLUSIONS: In the case of full-view 10 mA projection data, the presented AwTV-PRWLS shows potential improvement. However, in the case of sparse-view 80 mA projection data, the AwTV/TV-POCS shows advantage over the PRWLS strategies.
Keywords: X-ray computed tomography, low-mAs protocol, penalized re-weighted least-squares, adaptive weighted total variation, projection onto convex sets
DOI: 10.3233/XST-140437
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 4, pp. 437-457, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl